POLYASPARTIC FOUNDATION GUIDE

Complete guide to polyaspartic fundamentals

Understand polyaspartic polyurea through its definition, weathering, applications, test evidence, material comparisons and grade selection.

01 · Material definition

What Is Polyaspartic Polyurea?

Direct answer: Polyaspartic polyurea is a two-component coating formed by reacting a polyaspartic ester resin with an isocyanate hardener. Applications include building waterproofing, industrial corrosion protection and decorative flooring.

In Gaodun two-component coatings, Part A supplies isocyanate groups and the polyaspartic ester resin in Part B supplies secondary amine groups. These groups react to form substituted urea linkages. Follow the mixing ratio by mass in the current technical data sheet (TDS) for the finished coating grade.

Explore Raw MaterialsView product grades

02 · Outdoor weathering

Why consider polyaspartic polyurea for long-term outdoor use?

Direct answer: Aliphatic structures provide a basis for better color and appearance stability under UV exposure. Actual durability still depends on the full formulation, workmanship, substrate and environment.

For an exposed roof, consider sunlight, rainfall and temperature changes. For a coastal facility, identify whether the component is exposed to marine air, splashing or prolonged immersion. Check the coating grade, the full coating system and the evidence for that exposure.

03 · Application scope

Which waterproofing, protection and flooring applications are suitable?

For a seaside terrace, what are you protecting: a leaking slab, a floor that needs a wear layer, or a metal component? What is the substrate, and is it exposed to sun and rain, marine spray or immersion? Use those answers to choose the relevant system below.

Building Waterproofing

Do not apply N300 or N700 directly to unprepared tiles on a roof or terrace. For primary waterproofing, check that the tiles are firmly bonded, repair hollow or loose areas, remove contamination and prepare a clean, dry surface. Prefer N300 for prolonged outdoor exposure. Consider N700 for standard weathering requirements. With either coating, test the proposed system on the prepared tiles and verify adhesion before coating the full area. The same exposure criteria guide selection on concrete roofs. For exterior walls, consult the product-specific guidance.

Industrial corrosion protection

Consider N100 for non-critical exterior surfaces of equipment and vehicles. For structural steel exposed to coastal air, assess N500 as a heavy-duty protective topcoat and verify the primer and intermediate coat. For tanks and pipes, identify the exterior or lining. Linings, splash zones and prolonged immersion require separate verification.

Decorative Flooring

For a decorative flake floor on a courtyard, path or terrace, seal with N600, broadcast flakes into the N600 midcoat, then apply the N200 clear topcoat. Assess primary waterproofing separately if the area leaks. For parking areas, verify vehicle loads and slip resistance.

Enclosed, persistently damp kitchens or bathrooms are not routine first-choice applications. Do not directly overcoat rubber-asphalt layers, hollow or powdery surfaces, damp substrates or standing water without suitable treatment.

Explore ApplicationsView the six application procedures

04 · Interpreting tests

How should weathering, tensile and adhesion tests be read?

Direct answer: Check specimen identity, method, conditions, report source and applicability together. An individual number does not directly represent project service life.

Tensile strength
13.00 MPa under standard conditions. Third-party report TL26080331 (printed page 2) records one submitted sample set, T26060219. It gives no separate results by grade. For a particular N300 lot, check the certificate of analysis (COA) for that grade and lot number.
Elongation at break
177% under standard conditions. Third-party report TL26080331 (printed page 2) records one submitted sample set, T26060219. It gives no separate results by grade.
Substrate adhesion
Pull-off adhesion was 4 MPa on concrete, 7 MPa on tile and 5 MPa on steel. Third-party report TL26080331 (printed page 3) records one submitted sample set, T26060219. It gives no separate results by grade.
Artificial weathering
Gaodun reports 4,000 hours of in-house artificial weathering. Third-party report TL26080331 does not cover this test. This guide provides no basis for converting those hours into a service life or warranty period.

The third-party results apply to the submitted sample under the reported test conditions. For typical values, technical requirements and application parameters, consult the current TDS for the grade. For measured results for a particular shipment, match the grade and lot number to its certificate of analysis (COA).

View the test-evidence centerView the full report PDF

05 · Material comparison

How do polyaspartic coatings, polyurethane and waterproofing membranes differ?

Comparison itemPolyaspartic coatingPolyurethane coatingWaterproofing membrane
How the coating forms or the sheet membrane is installedTwo-component reaction forms a continuous coatingLiquid-applied filmSheet installation or torch application
Detail treatmentCan cover complex details; reinforcement remains necessaryBrush application to various detailsStrongly influenced by laps and detail treatment
Outdoor assessmentCheck aliphatic structure and weathering evidenceWeathering differs considerably by typeDepends on membrane type, protection layer and installation
Selection principleNo single material fits every project. Select according to substrate, environment, structure and maintenance.

06 · Grade selection

How do I select a Gaodun coating grade for my application?

Before choosing a grade, tell us about the surface. Which part of your terrace needs work? What is the substrate? What problem are you trying to solve, and is the surface exposed to marine air, splash or immersion? With only the location, grade selection is still open. The entries below describe systems for defined jobs.

N100Higher-hardness industrial surface protection

N100 protects non-critical exterior surfaces on equipment, construction machinery, vehicles and above-ground port facilities. It can also provide clear protection for outdoor wood. On coastal building exteriors made of concrete, securely bonded tile or stone, assess the coating system for the substrate. For primary waterproofing on roofs or terraces, assess N300 first for prolonged outdoor exposure and consider N700 for standard weathering requirements. Prepare existing tiles and verify adhesion before retaining them. For heavy-duty corrosion protection of steelwork, assess N500 with its specified coating system.

N200High-clarity finish

N200 is a finished, clear, wear-resistant topcoat. N-200A (N200A) is an HDI-based aliphatic polyisocyanate curing agent for coating formulations. This guide does not identify the curing agent used to formulate the finished N200 topcoat. Consult the approved N200 formulation to verify its raw materials. Assess primary waterproofing separately if the roof leaks. Verify intercoat compatibility and adhesion before applying N200 over N100, N300 or N700. N200 is the final clear wear coat over the flake-bearing N600 midcoat.

N300Highly flexible long-term outdoor waterproofing

Prefer N300 for primary waterproofing on concrete roofs and terraces with prolonged outdoor exposure. Consult its product sheet for exterior walls. If retaining tiles, prepare the surface and verify adhesion first.

N500Industrial steel corrosion protection

Consider N500 as a heavy-duty protective topcoat on structural steel exposed to coastal air. Check the primer, intermediate coat and specified dry film thickness. Splash zones, prolonged immersion and linings require separate verification.

N600Outdoor abrasion-resistant flake flooring

For a decorative flake finish over sound waterproofing, use the following three coats after confirming the substrate and compatibility. Investigate a leaking terrace before specifying this finish.

  1. Base sealing coat: N600.
  2. Midcoat: N600. Broadcast decorative flakes into this coat.
  3. Clear wear-resistant topcoat: N200.

Assess leaks separately. For parking areas, also verify vehicle loads and slip resistance.

N700Flexible outdoor waterproofing

Consider N700 for primary roof or terrace waterproofing with standard weathering requirements. Prefer N300 for prolonged outdoor exposure. To retain existing tiles, check their bond, repair hollow or loose areas, prepare the surface and verify adhesion on a test patch.

For final selection, provide city, substrate, area, exposure, color requirements and cracks or corrosion. Confirm through site inspection and sample-panel tests.

View the N-200A curing agent data
Scope of this guidance

This guide supports basic understanding and preliminary selection. It does not replace project design, TDS, SDS, batch COA or site application plans. Substrate, consumption, thickness, workmanship, environment and maintenance affect results.

Article translations follow the Simplified Chinese source. Translated documents, narration and subtitles are labeled; original reports, recordings and on-screen labels remain available.

Multilingual PDF / TDS

Need a grade matched to your application?

Provide city, substrate, area, whether exposure is permanent, and details of cracks, leaks or corrosion.

Submit a technical inquiry

Frequently asked questions

Which coating should I use to refurbish a seaside terrace?

Identify the purpose, substrate and exposure first. For a leaking slab, assess primary waterproofing. For decorative flake flooring, assess N600 with an N200 clear topcoat; any underlying waterproofing must be selected separately. For a metal component, distinguish coastal atmospheric exposure, splash and prolonged immersion before specifying a system. If retaining old tiles, repair loose or hollow areas and test adhesion on the prepared tiles before full application.

View product selection