N700 · OUTDOOR WATERPROOFING

Outdoor Value Option

N700 Flexible Outdoor Waterproofing Polyaspartic Polyurea Waterproofing Coating

N700 is a two-component aliphatic polyaspartic polyurea coating for standard outdoor waterproofing on concrete roofs, terraces and sound existing tiles. Prepare existing tiles and verify adhesion on a trial area before coating.

Flexibility for roof conditionsCovestro HDI (TDS V2.6)A:B = 1:1 by weight
Illustration of a light gray N700 polyaspartic polyurea waterproof coating on a rooftop terrace
FlexibilityAccommodates roof temperature changes
A+BAliphatic two-component system
1:1Mixing ratio by weight
1.3 kg/m²Indicative roof consumption

N700 packaging

Gaodun N700 2 kg kit packaging with 1 kg each of Parts A and B

2 kg kit

Part A 1 kg + Part B 1 kg

Gaodun N700 20 kg kit packaging with 10 kg each of Parts A and B

20 kg kit

Part A 10 kg + Part B 10 kg

MATERIAL STRUCTURE

Parts A and B
Aliphatic polyaspartic system

N700 TDS V2.6 specifies a Covestro HDI (TDS V2.6). Confirm the raw-material source for the supplied batch against its technical documents. Mix Parts A and B on site at 1:1 by weight to form a continuous waterproof coating.

A
HDI aliphatic isocyanate componentCovestro HDI (TDS V2.6); verify the source for the supplied batch
+
B
Polyaspartic Ester ResinTwo-component reaction and film formation on site
A:B = 1:1 → Continuous waterproof coating

PRODUCT POSITIONING

Outdoor waterproofing for roofs, terraces and tile refurbishment

Main applications

For roofs, terraces and tile refurbishment with standard weathering requirements.

Selection benefits

Balances an aliphatic weather-resistant structure, application suitability and overall project cost.

Use limitations

Not recommended for enclosed damp kitchens or bathrooms, or for direct coating over rubber-asphalt waterproofing.

WATERPROOF APPLICATIONS

N700 building-waterproofing applications

Outdoor aliphatic protection, suitability for common substrates and project cost considerations for roofs, terraces and sound tiled surfaces.

Illustration of N700 refurbishment on a standard concrete roof
Application illustrationStandard roof refurbishmentContinuous coating · Outdoor waterproofing
Illustration of N700 terrace waterproofing
Application illustrationRoof and terrace waterproofingWaterproof refurbishment · Project cost considerations
High-angle view of a worker roller-applying light gray polyaspartic polyurea waterproof coating over existing rooftop tiles
Application illustrationRefurbishing sound tiled surfacesTile-overcoating option · Verify substrate adhesion first

These images illustrate application effects and are not records of specific projects. Confirm consumption, film thickness and detail treatment against the substrate and project requirements.

Performance and test evidence

Shore hardness

Shore A75

Manufacturer’s technical value

Tensile strength

≥10 MPa

Manufacturer’s requirement

Elongation at break

≥150%

Manufacturer’s requirement

Third-party test specimen

One submitted sample, T26060219, had a tensile strength of 13.00 MPa and an elongation at break of 177% under the standard conditions of GB/T 16777-2008. Report TL26080331 lists the N100–N700 series in the specimen name. Results apply to the submitted specimen and test conditions, with no grade-specific results. Refer to the N700 TDS, COA and batch documents for supplied specifications.

View test report (PDF)

PRODUCT SPECIFICATION

N700 specifications and application information

Adjust actual consumption for substrate roughness, absorption and design thickness.

Product type
Two-component aliphatic polyaspartic polyurea
Mixing ratio
A:B = 1:1 (by weight)
Suitable substrates
Concrete and sound tiled surfaces
Application methods
Roller, brush, squeegee or spray
Indicative waterproofing consumption
1.3 kg/m², applied in multiple coats
Indicative film thickness
approximately 1.2 mm
Pot life of mixed Parts A and B
Approximately 1 hour at 25 °C
Raw-material system
Covestro HDI (TDS V2.6)

APPLICATION SYSTEM

Indicative system for roofs and tile refurbishment

Before coating, confirm a sound, dry and clean substrate and address hollow tiles, oil, cracks and unstable existing layers.

  1. 01

    Inspect and clean the substrate

    Abrade and remove dust, oil, hollow areas and loose material. Check tiled surfaces particularly carefully for soundness.

  2. 02

    Reinforce cracks and details

    Provide suitable reinforcement at cracks, internal and external corners, drains and roof penetrations.

  3. 03

    Measure Parts A and B accurately

    Mix thoroughly at A:B = 1:1 by weight and finish application within the pot life.

  4. 04

    Apply successive cross coats

    Apply 2–3 coats in alternating directions. Confirm that the previous coat is ready for recoating before applying the next. Indicative total consumption is 1.3 kg/m², corresponding to approximately 1.2 mm of film thickness.

Important:Hollow tiles, damp substrates and unstable existing waterproofing directly affect final adhesion and waterproofing.

MODEL SELECTION

N700 or N300?

MODEL TECHNICAL DATA SHEET

N700 dedicated technical data sheet

Gaodun N700 dedicated technical data sheet cover and A+B packaging

Covers product positioning and packaging, technical data, substrates, application and storage. Desktop edition: 5 pages. Mobile edition: 7 pages.

V2.6 · 2026-10-21
Technical preparation/review responsibility: Shenzhen Gaodun New Materials Co., Ltd.

PROJECT SUPPORT

Confirm the substrate before choosing the N700 system

Provide city, substrate, area and details of cracks or leaks. Gaodun can advise on grades and indicative consumption.

Frequently asked questions

What are the main applications of N700?

For waterproofing concrete roofs, tiled roofs and terraces, choose N300 for long-term weather resistance and N700 for standard weather resistance. Check that old tiles are sound, dry and free from hollow areas before surface preparation and an adhesion trial.

Roof Waterproofing Selection Guide

Can N700 be applied over existing tiles?

Check that the tiles are sound and dry. Repair hollow or loose areas, remove contamination and verify adhesion on a test patch. Once adhesion is confirmed, select N700 for standard weather exposure or N300 for long-term weather resistance. Light-grey N700 covers the tile pattern. If a tiled terrace leaks and the pattern must remain visible, trace the water entry and specify the primary waterproofing first. Test appearance, adhesion and intercoat compatibility on the existing tile. N200 clear topcoat alone will not repair a leak.

How much area does 1 kg of N700 cover?

At the indicative total application rate of 1.3 kg/m², 1 kg of mixed Parts A and B covers about 0.77 m², with an indicative film thickness of about 1.2 mm. At that rate a 20 kg kit covers about 15.4 m². Actual consumption depends on substrate absorption, detail reinforcement and application losses.

Can I recoat one hour after mixing N700?

The one-hour figure does not establish a recoat interval. It is the indicative pot life of mixed Parts A and B at 25 °C. Apply the next coat once the previous coat meets the recoat conditions in the applicable TDS and on site.

Does the reported 177% elongation apply to every batch of N700?

No. The 177% result in TL26080331 applies only to submitted sample T26060219 under the reported test conditions. The report gives no separate result for N700. Gaodun specifies elongation at break of ≥150% for N700. Confirm the supplied batch against its TDS and certificate of analysis (COA).