N200 · TRANSPARENT TOPCOAT
Clear finish · Wear protectionN200 High-Clarity Grade Polyaspartic polyurea clear finish
N200 is a two-component, abrasion-resistant clear topcoat for tile, stone, wood and decorative flooring. Approximately 96% solids is a typical company value, subject to the batch COA. Roof waterproofing requires a separate primary waterproofing layer.

Packaging sizes
2 kg per set
Part A 1 kg + Part B 1 kg
20 kg per set
Part A 10 kg + Part B 10 kg
TRANSPARENT PROTECTION
Preserve original texture
Add clear wear protection
N200 protects tile, stone, wood and decorative flooring without covering their appearance. Outdoor systems require substrate-stability, compatibility and project testing.
PRODUCT POSITIONING
Clear finish, not a replacement for the main waterproofing layer
Core function
Forms a continuous clear film on prepared substrates or compatible coatings to improve wear resistance and surface protection.
Suitable surfaces
Tile, stone, wood, decorative flake flooring and clear finishes over waterproofing/protection coatings.
Selection principle
Confirm adhesion, existing-coating compatibility and clarity requirements before setting coats and consumption.
TRANSPARENT APPLICATIONS
N200 clear-finishing applications
A continuous clear layer preserves original color and texture while supporting wear resistance, cleaning, maintenance and outdoor protection.



The first three images illustrate application effects; the last three images show coating samples. N200 is a clear polyaspartic topcoat for compatible coating systems. Confirm substrate preparation, intercoat adhesion, compatibility and appearance on a sample first. It does not replace the main waterproofing layer.
Typical properties and test evidence
Typical company value; refer to batch COA
Company technical value
Reference at 25°C. Confirm the recoating interval separately.
Indicative film thickness: approx. 0.96–1.0 mm. Apply thin, even coats as described in the TDS. Verify actual coverage and film thickness on a site trial.
PRODUCT SPECIFICATION
N200 specifications and selection
Actual properties and consumption depend on batch documents, substrate and site tests.
- Product type
- Two-component clear polyaspartic finish
- Product appearance
- High clarity
- Reference solids
- Approximately 96% (typical, subject to batch COA)
- Mixing ratio
- A:B = 1:1 (by weight)
- Suitable substrates
- Tile, stone, wood and decorative flooring
- Main purpose
- Clear finishing, wear and weather protection
APPLICATION SYSTEM
Four clear-finishing applications
- 01
Tile and stone
Preserves color and texture; confirm cleanliness, soundness and adhesion before coating.
- 02
Clear wood coating
Surface protection retaining visible grain; check moisture and small-area compatibility first.
- 03
Decorative flake flooring
Seals decorative particles with a clear finish to improve surface wear resistance, cleaning and maintenance.
- 04
Waterproofing and corrosion-protection systems
Clear protection over compatible coatings; confirm intercoat adhesion and application windows.
Note: N200 is a clear finishing/protection layer and cannot independently replace a main waterproofing layer requiring thickness, flexibility and crack resistance.
SYSTEM SELECTION
Choose the system by primary use
Verify intercoat compatibility, adhesion and appearance on a trial area before combining coats.
N100
Industrial surface protection. Evaluate N200 if a clear wear-resistant finish is required.
N300
Primary waterproofing of roofs, terraces or sound tiles with long-term weathering requirements. Evaluate N200 as needed for clear finishing.
N700
Primary waterproofing of roofs, terraces or sound tiles with general weathering requirements. Evaluate N200 as needed for clear finishing.
N600
Decorative flake flooring. Use N200 to seal flakes as specified for the system.
N200 FAQ
Clear-finish FAQs
Can N200 alone waterproof a roof?
No. N200 is a clear topcoat. For primary waterproofing of roofs, terraces or sound tiles, evaluate N300 first for long-term weathering requirements and N700 for general weathering requirements. Once the primary layer is complete, evaluate N200 against the recoating window, intercoat compatibility and adhesion.
Can it be coated directly over tiles?
For clear surface protection, trial N200 on a small area of sound, clean, dry and oil-free tile to verify adhesion and appearance. If the goal is to stop a leak, assess the primary waterproofing system first.
Why is it used on decorative flooring?
In the Gaodun decorative flake flooring system, N600 primes the substrate and forms the base coat that receives the flakes. N200 seals the flakes with a clear, wear-resistant finish that preserves their appearance. Verify wet slip resistance of the finished system for wet or trafficked areas.
How is it combined with N300 or N700?
Complete the primary waterproofing layer first, then verify the recoating window, intercoat compatibility and adhesion. About 40 minutes at 25 °C is the indicative working time of mixed Parts A and B. Confirm the recoat interval and time before foot traffic separately using the supply documents and actual curing conditions.
How do N200 and N200A differ?
N200 is the finished two-part clear topcoat kit for mixing and application on site. N-200A (also written N200A) is an aliphatic polyisocyanate hardener raw material for formulation. Order N200 for the finished kit.
View the N200A raw materialDoes every compatible system require N200?
On N100, N300 and N700 systems, consider N200 when a clear topcoat is required and an intercoat adhesion, compatibility and appearance trial passes. Use N200 on N600 flakes as specified for the flooring system. For wet or trafficked flooring, verify wet slip resistance for the full system.
Can N200 be applied over cracks, debonded tiles or a leaking substrate?
Inspect and address cracks, debonded tiles or water ingress before evaluating N200 as a clear topcoat. For a leaking roof or terrace, assess and repair the primary waterproofing system as required by the project.
Does the roughly 96% solids figure certify the solids content of my N200 batch?
No. About 96% is a typical company value in the N200 TDS. The 92.6% non-volatile matter in TL26080331 was measured on submitted sample T26060219, with no separate result for N200. Check the certificate of analysis (COA) for the supplied batch.
MODEL TECHNICAL DATA SHEET
N200 dedicated technical data sheet

Covers positioning, application samples, typical properties, application and storage. Desktop: 5 pages. Mobile: 7 pages.
V2.6 · 2026-10-21
Selection guidance revised ·
Technical preparation/review responsibility: Shenzhen Gaodun New Materials Co., Ltd.
For primary roof waterproofing, evaluate N300 first for long-term weathering requirements and N700 for general weathering requirements. The listed N100 combination applies to industrial surface protection. Select the primary roof waterproofing layer by roof system requirements.
PROJECT SUPPORT
Provide substrate and purpose for an N200 clear-finishing system
Provide application location, substrate, existing coating, area and clarity requirements.