← Knowledge Center

Current TDS: N300 and N700 reference total application rate is 1.3 kg/m² for approximately 1.2 mm of film. The original footage and audio record an earlier application example. Use the current TDS and a site trial to confirm consumption. The 20 years shown in the footage refer to the design working life of the roof waterproofing system. Consult the written project terms for the coating warranty. At about 19 seconds, the brand name in the English caption should read Gaodun (高盾).

Tiled Roof and Terrace Waterproofing Application Procedure

Original soundtrack with time-coded technical notes. Download English technical guide captions (VTT)

Open the high-resolution original with its original soundtrack

VIDEO DESCRIPTION

Video Description

How to waterproof a tiled roof or terrace over sound existing tiles, from adhesion checks to the final coat.

How can waterproofing on roof and terrace tiles address sunlight, cracking and long-term durability together?

GB 55030—2022, General Code for Waterproofing of Building and Municipal Engineering, specifies a roof-waterproofing design working life of at least 20 years. To address long-term waterproofing, the Gaodun polyaspartic procedure for tiled roofs has eight main steps. For waterproofing concrete roofs, tiled roofs and terraces, choose N300 for long-term weather resistance and N700 for standard weather resistance.

  1. Step 1: Inspect and prepare the substrate.

    Tile-preserving refurbishment can be considered when existing tiles are securely bonded, the substrate meets coating requirements, and a trial confirms compatibility and adhesion. Remove and repair locally hollow or loose tiles before abrasion and cleaning. Investigate widespread hollow areas or continuing seepage before selecting the refurbishment system.

  2. Step 2: Prepare and fill joints.

    Remove loose old joint filler. Where ordinary joints or stable cracks require repair, form a groove approximately 3–5 mm wide while controlling depth to avoid damaging existing waterproofing.

    Mix Parts A and B at the specified ratio, then use Gaodun's validated combination of mixed coating to dry cement at 1:1 or 1:2 by weight, adjusted to joint conditions. Fill and compact flush. Expansion joints and continuously moving cracks require separate specialized treatment.

  3. Step 3: Reinforce wall junctions.

    Use one reinforcing fabric within three coats at wall junctions: apply the first polyaspartic coat, embed the compatible glass-fiber fabric while wet, press and saturate it, then apply two further coats. Avoid wrinkles, voids or exposed fabric.

  4. Step 4: Venting and pipe penetrations.

    Where required by roof construction and substrate moisture, install an effectively connected venting system. Seal and reinforce vent pipes and other penetrations using one fabric within three coats.

  5. Step 5: Reinforce other details.

    Treat vulnerable corners, drains and gutter transitions to the detail design, ensuring tight terminations and free drainage.

  6. Step 6: Measure and mix accurately.

    Before each coat, weigh and mix Parts A and B at the grade's specified weight ratio and use within its working time. Follow the tile procedure on tiles. The 20–30% thinner addition for the first concrete coat applies only to concrete penetration sealing.

  7. Step 7: Apply cross coats over the main area.

    Apply three even coats. Indicative total consumption is 1.3 kg/m² for approximately 1.2 mm of film, excluding additional detail reinforcement and application losses.

    An indicative 2–3 hours between coats must be checked against product requirements, site temperature/humidity and cure. Dry-film thickness follows the project design and grade documents and must be checked on site.

  8. Step 8: Inspect and cure.

    Ensure continuity between reinforced details and the main coating. Inspect and repair pinholes, bubbles and missed areas. Complete curing and project waterproofing acceptance before opening for use.

    The finished Gaodun coating is continuous and dense, intended to provide UV and wear resistance and flexible crack accommodation, with surface water beading and runoff.

    Twenty years is a design requirement for the roof waterproofing system. Long-term durability requires materials, design, workmanship and maintenance together.

    Since 2016, Shenzhen Gaodun has focused on polyaspartic polyurea, developing for long-term waterproofing and corrosion protection and verifying for building and industrial durability.

This video records an actual polyaspartic polyurea application procedure. Assess the application, substrate type and condition, product grade, A/B ratio, consumption, successive coats and curing conditions together.

APPLICATION INFORMATION

Application Information

Material system
Polyaspartic polyurea
Category
Application procedure
Models mentioned
N300, N700
Publisher
Shenzhen Gaodun New Materials Co., Ltd.
Purpose
Application procedure or case reference
Before application
Model-specific TDS, SDS, substrate and environmental conditions

Publisher: Shenzhen Gaodun New Materials Co., Ltd.
First published:

Content limits: Application videos and case records explain particular processes and project conditions. Before work, check the substrate, environment and details against the model-specific documents and a site trial.