WEBVTT

00:00:00.000 --> 00:00:12.000 line:8%
For primary tiled-roof waterproofing, assess N300 for long-term exposure and N700 for standard weathering needs.

00:00:12.000 --> 00:00:18.000 line:8%
20 years refers to the roof waterproofing system’s design life. Check the written terms for the coating warranty.

00:00:18.000 --> 00:00:23.500 line:8%
The brand is Gaodun (高盾).

00:00:23.500 --> 00:00:32.500 line:8%
Check tile bond and repair local loose, hollow or damaged areas. Investigate widespread hollow tiles or ongoing seepage.

00:00:32.500 --> 00:00:40.900 line:8%
Clean and dry the prepared tiles. Verify compatibility and adhesion on a test patch before deciding to coat existing tiles.

00:00:40.900 --> 00:01:12.600 line:8%
Clean joints and use the verified repair detail. Assess ordinary joints and stable cracks separately from moving or structural cracks.

00:01:13.000 --> 00:01:31.800 line:8%
Reinforce junctions to the project detail. Check saturation and continuity, especially at corners.

00:01:32.200 --> 00:01:54.100 line:8%
Assess ventilation needs against roof construction and moisture. Check pipe penetrations, drains and gutter junctions.

00:01:54.500 --> 00:02:07.600 line:8%
Weigh A and B for each coat using the selected grade’s TDS mass ratio. Concrete-sealer thinning does not apply to tiled substrates.

00:02:07.600 --> 00:02:22.000 line:8%
N300/N700 TDS reference total over three coats: 1.3 kg/m² for about 1.2 mm of film. Allow separately for details and losses.

00:02:22.000 --> 00:02:34.100 line:8%
Confirm recoating against grade, site conditions and cure. Verify dry-film thickness against the design.

00:02:34.400 --> 00:02:57.800 line:8%
After curing, check continuity, pinholes and missed areas. Repair and complete project acceptance before opening for use.

00:02:58.300 --> 00:03:19.100 line:8%
Service life depends on materials, design, installation and maintenance. This recording provides no project-specific warranty.