| Concrete roofs | Sound concrete and cement mortar | N300 (long-term) N700 (standard) | Main waterproofing layer | Typical total for primary waterproofing: about 1.3 kg/m² across 2–3 coats. | Moisture, strength, cracks and details |
| Roof terraces | Concrete and sound existing coatings | N300 (long-term) N700 (standard) | Main waterproofing layer | Typical total for primary waterproofing: about 1.3 kg/m² for approximately 1.2 mm of film. | Drainage, parapets and exposed service |
| Tile refurbishment | Sound tiles | N300 (long-term) N700 (standard) N200 (optional finish) | N300 or N700 provides primary waterproofing. N200 is an optional clear wear-resistant topcoat. | N300 or N700: about 1.3 kg/m² in total for approximately 1.2 mm of film. Allow separately for any N200 topcoat. | Repair hollow or loose tiles and cracks first. Clean, dry and abrade the tiles, then test coating adhesion to the tile. Test intercoat adhesion separately if adding a topcoat. |
| Decorative exterior-wall waterproofing | Concrete, mortar and decorative surfaces | N300 | Continuous waterproofing, outdoor weathering and color | Determine consumption per coat from substrate absorption, target film thickness and a site trial. | Cracks, existing-layer soundness and color |
| Decorative flake flooring | Concrete, cement mortar and sound tiles | N600+N200 | N600 flake layer; N200 clear wear-resistant finish | N600 sealer + N600 intermediate coat with broadcast flakes + N200 clear topcoat | Check substrate moisture, traffic loads and wet slip resistance. Abrade sound tiles and test adhesion. Roof terraces need separate primary waterproofing. |
| Steel protection | Carbon steel and prepared metal | N500 | N500 heavy-duty anticorrosive topcoat with a project-specific primer and intermediate coat | Project-designed primer/intermediate/finish | Preparation grade, corrosion category and target dry-film thickness |
| Coastal port protection | Steelwork, pipe exteriors and tank exteriors | N500 | N500 heavy-duty anticorrosive topcoat for atmospheric exposure on coastal steelwork | Design for exposure and compatible coating layers | Check primer, dry-film thickness and maintenance interval. Splash exposure, prolonged immersion and linings require separate validation. |
| Industrial equipment, vehicles and port facilities | Prepared metal, existing coatings and associated concrete | N100 | Non-critical exterior protection, waterproofing and wear maintenance | Confirm consumption, thickness and primer by project | Rust removal, old-paint compatibility and exposure; mask critical components |
|---|
| Outdoor wood | Timber floors, clad walls and railings | N100 | Clear surface waterproofing, protection and wear maintenance | Confirm consumption, thickness and primer by project | Species, moisture, oils/waxes, clarity and adhesion |
|---|
| Coastal-building surface protection | Concrete, sound tiles and stone | N100 | Higher hardness, visible texture and wear/waterproofing maintenance | Confirm consumption, thickness and primer by project | Check cracks, detailing and drainage. Verify adhesion to tile and stone. For primary roof waterproofing, prefer N300 for long-term exposure or consider N700 for standard weathering. |