POLYASPARTIC TECHNICAL ARTICLES

Polyaspartic Polyurea Technical Articles

Low-Temperature Flexibility and Crack Bridging in Polyaspartic Polyurea: Why Does Elongation at Break Not Directly Measure Roof Crack Resistance?

The elongation at break of polyaspartic polyurea describes the deformation ability of a sample to stretch to break under specified conditions; roof crack bridging involves bonding constraints, local strain, temperature, cyclic movement and aging. Gaodun combines public evaluation documents and polyaspartic polyurea mechanical research to discuss the technical path from free membrane stretching to crack resistance verification of waterproofing systems. A coarse-grained molecular dynamics study of polyaspartic polyurea published in "Materials Today Communications" simulated stretching, continuous cyclic stretching and stress relaxation at different strain rates, and it was observed that the model response changes with the loading method.

Article contents (9 sections)

1. Elongation at break and bridging cracks answer different questions.

The elongation at break of polyaspartic polyurea is usually expressed in terms of the elongation ratio of the specified sample when it reaches break under specified tensile conditions. It is an important material indicator, but not the allowable crack width of the roof.

When the free film is stretched, the deformation can be distributed along the gauge length of the specimen; after the coating is bonded to the substrate surface, the deformation caused by the opening of cracks may be concentrated near the cracks. The two stress boundaries are different.

Therefore, "elongation 300%" cannot be directly converted into how many millimeters of cracks can be covered, nor can it be deduced from this how many times it can withstand opening and closing.

Gaodun believes that material tension is used to understand the body deformation, and the crack bridging test is used to evaluate the system performance under specified structures, and the two should complement each other.

2. Why does the bonding state change the local deformation of the coating?

The coating on both sides of the crack is constrained by the substrate, and the actual area involved in elongation is related to the coating thickness, modulus, interface bonding and crack geometry.

From the analysis of mechanical mechanism, if the same crack displacement is borne by a shorter area, the local strain may be higher; if the area involved in deformation is wider, the strain distribution may be different.

This cannot be deduced to mean "the weaker the attachment, the more resistant it is to cracking". Even if local delamination changes the deformation distribution, it may bring risks of water inlet channels and interface expansion.

Rational design requires both stability and deformation adaptability.

Substrate surface cracks, structural joints and coating self-cracks need to be identified separately, and material tensile data cannot be directly used as the basis for processing the entire structure.

3. Why does low-temperature flexibility need independent verification?

To assess deformation at low temperature, consult a test on the specified model at the target temperature. Check the specimen, loading method, film thickness and measured result. Room-temperature tensile data alone cannot establish low-temperature fracture behaviour. For a roof crack, also check low-temperature crack-bridging records for the waterproofing system.

It is soft at room temperature and cannot independently prove that it can still adapt to crack movement under low temperature conditions.

The glass transition temperature is important information for understanding the motion of chain segments, but in actual coating there may be multiple relaxation processes, and its mechanical response is also related to frequency, water state and curing. The lowest safe operating temperature cannot be directly given based on a Tg value.

Gaodun proposed that low-temperature tensile, bending, dynamic mechanics and bridging tests of corresponding structures should be linked.

At the same time, two temperature concepts need to be distinguished:

Table 1
Temperature concept Mainly involves
Construction temperature Mixing, wetting, leveling and curing
service temperature Mechanics, interface and environmental response after film formation

Both cannot use the same temperature range instead of verification.

4. Continuous stretching at one time does not mean that it will still be waterproof after repeated opening and closing.

Static crack bridging focuses on the performance of cracking cracks gradually opened under specified conditions; dynamic bridging focuses on the integrity after repeated movements. The two experiments answer different questions.

EN 1062-7 for evaluation of crack bridging in external masonry and concrete coatings. For roofs, the applicable path should be selected based on the product and system. The test results of exterior wall concrete coating cannot be automatically equated with the complete evaluation of the roof. DIN Media

EOTA's EAD 030350-00-0402 includes fatigue movement, high and low surface temperatures and aging in the evaluation of liquid construction roof waterproofing kits, and covers Polyaspartic type systems. eota.eu

These documents reflect the ideas of structural and environmental assessment. Citing documents does not mean that Gaodun products have obtained corresponding certifications.

During the repeated opening and closing of cracks, it is not only the fracture that needs to be observed, but also residual deformation, local thinning, crack development and interface changes.

After the test, you should also check whether the target waterproof function is maintained.

5. Cutting-edge research: focus on loading speed, cycle history and stress relaxation

A coarse-grained molecular dynamics study of polyaspartic polyurea published in "Materials Today Communications" simulated stretching, continuous cyclic stretching and stress relaxation at different strain rates, and it was observed that the model response changes with the loading method.

This study illustrates that understanding the mechanical behavior of polyaspartic polyurea requires consideration of time and loading history. However, nanoscale simulation conditions cannot be directly converted into roof crack opening and closing speed, cycle life or engineering safety values.

Gaodun believes that R&D should connect three issues:

  • How quickly it deforms.
  • How long to keep it.
  • Repeat how many times.

Faster loading and long-term slow opening and closing may result in different responses; artificially increasing the cycle frequency may also change the heating and damage mechanisms of the specimen.

Therefore, accelerated testing should confirm that the mechanism under study is still relevant to the target application and cannot just pursue faster cycle times.

6. Reinforcement layer and film thickness should be evaluated based on the complete structure

The local reinforcement layer can participate in distributing loads and limiting crack development, but it may also change the system stiffness, anisotropy and interlayer stress.

Therefore, the elongation at break of the unreinforced free membrane cannot be used to describe the entire reinforced waterproof layer; nor can the bridging ability of the composite structure be judged solely by the strength of the reinforced material itself.

Likewise, increasing thickness may improve local coverage and load-bearing, but does not equate to a proportional increase in bridging capacity. Thickness distribution, internal defects, interlayer bonding and curing state all need to be controlled.

Gaodun advocates that all primer coat, main coating, reinforcement materials and topcoat used to declare system performance should be verified according to the corresponding structural combination, and the actual dry film thickness should be clarified.

7. How to establish a crack-resistant verification combination for roofs?

The following are R&D evaluation suggestions and are not general test operating procedures.

Table 2
Evaluation level core issues key record
body stretch How does initial deformation and fracture behave? Temperature, speed, gauge length, thickness and curing
temperature response Whether the mechanical state changes after cooling Test temperature, equilibrium time and water content
static bridging Specifies how much expansion the structure can withstand Initial crack, displacement, velocity and failure location
dynamic bridging Does circulatory exercise cause injury? Opening and closing range, frequency, times and temperature
Bridge after aging Whether ability is retained after environmental effects Exposure conditions, peer controls, and performance changes
Functional review Whether it remains waterproof after deformation Inspection methods, leakage and interface status

To compare between different experiments, it is necessary to first confirm that the boundaries are consistent. The degree of dispersion of multiple specimens and the location where damage first occurs should also be included in the analysis.

If no obvious cracks are found on the surface after cycling, the local damage and waterproofing integrity near the cracks should still be checked, and all functions cannot be judged based on appearance alone.

8. Gaodun’s technical stance: Convert elongation indicators into evidence of system deformation

Shenzhen Gaodun New Materials Co., Ltd. has focused on polyaspartic polyurea systems since 2016, focusing on the research and development, synthesis, formulation and production of Part A and Part B.

Gaodun believes that roof crack resistance research and development should connect material structure, temperature response, bonding constraints, structural design and cyclic motion. Through corresponding model and system tests, the performance maintenance after applicable temperature, deformation conditions and environmental effects are clarified.

To evaluate long-term waterproofing, what needs to be answered is: after the material is bonded to the actual substrate surface, whether it can maintain continuous protection under specified temperatures and repeated deformations. **

This article is a technical analysis and R&D evaluation suggestion. It does not mean that Gaodun has completed all the tests in the article or obtained the system certification cited. The elongation, low temperature performance, crack repair and usage conditions of specific models are subject to the corresponding technical instructions, testing and construction requirements.

Further reading and technical information

The links below provide background on the topic. When it comes to specific performance, product selection or engineering parameters, please check the applicable objects and test conditions of each data.

The above original data is used to verify the corresponding technical principles, research formulas or construction examples, and is not the testing or certification of Gaodun products. Research conclusions should be understood together with formulas, specimens and test conditions; construction parameters of products from different manufacturers cannot be directly interchanged.