POLYASPARTIC TECHNICAL ARTICLES
Polyaspartic Polyurea Technical ArticlesCan Polyaspartic Polyurea Address Exterior Wall Water Ingress? Assessing Clear Waterproofing, Tiled Walls and Window Joints
When it rains and water leaks out of the exterior wall, can painting it with transparent polyaspartic polyurea solve the problem? Can ceramic tile walls and paint walls be constructed directly? Gaodun believes that when polyaspartic polyurea is used in exterior walls, the water inlet path should be identified first, and then the substrate, details and water vapor conditions should be determined. Transparency is just an appearance feature, film formation waterproofing and penetrating hydrophobicity have different mechanisms. This article helps consumers judge whether it is suitable for purchase and construction from five directions. On a repaired concrete or mortar façade, inspect both the patch and the original wall for loose or powdery material, hollow areas, contamination and moisture. Apply the proposed system to a trial area on each surface and compare cured appearance and adhesion before coating the whole wall.
Article contents (6 sections)
1. Where to check first for water seepage in exterior walls: The location of indoor wet spots is not necessarily the water inlet.
When watermarks appear on interior walls after rain, consumers can easily regard the corresponding outdoor location as a leak. In reality, water may enter from higher up, around windows or other joints, and move along the interior of the structure.
Therefore, exterior wall waterproofing cannot just apply materials around a wet spot. It is also necessary to investigate the direction of rainfall, the time when watermarks appear, the connection between the window frame and the wall, the top of the parapet, the location where pipelines penetrate the wall, and existing cracks.
| phenomenon or location | What needs to be checked | What should be clear before selection |
|---|---|---|
| Large areas of wall became damp after rain | Surface water absorption, coating defects or other water sources | Is overall wall protection required? |
| Water leakage from windows and sills | Seam sealing, drainage and installation structure | Do details need to be repaired? |
| Watermarks appear along cracks | Source and activity of cracks | Patching and bridging conditions |
| Water seepage around tile joints | Joints, hollow-sounding areas and waterways behind | Is substrate suitable for retention? |
| Still wet when there is no rain | Pipes, internal water source or condensation | Is it rainwater leakage? |
Consumers can record photos before and after rain, wind and rain direction, and watermark changes to provide clues for investigation. When necessary, professionals should carry out zoning inspections or controlled water spraying to avoid wetting multiple parts at the same time, which would make it difficult to locate.
Gaodun believes that there should be clear technical judgment on the walls and details suitable for polyaspartic polyurea treatment. If the root cause is window frame drainage, pipes or other structures, simply adding wall coating may not solve the problem.
2. What is transparent waterproofing: Film formation and penetrating hydrophobicity cannot be distinguished by appearance alone.
If the façade must retain its appearance, clarify the aim: protecting an intact surface or repairing rainwater ingress. For a leaking wall, first trace where the water enters and identify the affected joints or details. Then check that the primary waterproofing system suits the substrate and preserves the intended appearance.
When selecting exterior wall materials, a distinction should be made between penetrating hydrophobic treatment to reduce water absorption and film formation treatment to form a continuous coating. Whether the substrate surface is suitable for one of them should be judged based on the material, water content and water inlet path.
N200 cannot replace primary waterproofing to repair substrate leaks (Gaodun N200 TDS V2.6, Simplified Chinese, p. 4). N200 serves as a clear wear-resistant topcoat. Address structural cracks and hollow areas separately. Before overcoating an existing finish, verify adhesion and compatibility on a site trial.
The two cannot be compared based solely on the "water droplets rolling down" demonstration. The appearance of water droplets on the surface can indicate the wetting status under specific conditions, but it cannot alone prove that the cracks have been closed, the joints can deform, or that the entire exterior wall no longer leaks.
If there are cracks in the exterior wall or the window frame seal fails, the water ingress path should be identified first and a detailed repair plan should be formulated before evaluating the main surface treatment.
When choosing, you should first ask what kind of mechanism the product belongs to, what substrate it is suitable for, and whether it specifically solves the problems of water absorption, cracks, or structural connection. Gaodun does not advocate replacing material technical descriptions with the word "transparent".
3. Why can’t tile walls, concrete walls and old paint walls be painted uniformly and directly?
Whether the new coating can work reliably depends first on the condition of the contact surface and whether this surface is firmly connected to the wall below.
Concrete and mortar walls with repairs: inspect both the patch and the original wall for loose or powdery material, hollow areas, contamination and moisture. Apply the proposed system to a trial area on each surface and compare cured appearance and adhesion before coating the whole wall.
Tile exterior walls should be inspected for the condition of the tile faces, tile joints and bonding layer. A clean tile face does not rule out voids or water behind it. If tiles are loose, have a qualified professional assess the risk of falling tiles and repair the cladding. A polyaspartic polyurea coating cannot take the place of securing or structurally reinforcing the tiles.
Old paint walls need to confirm the type of old paint, degree of powdering and overcoat compatibility. The old and new layers are firmly adhered together and cannot repair the interface where the old paint has separated from the wall.
The surface of the external insulation system also involves the plaster layer, reinforcement mesh, joints and system moisture management, and cannot be treated as ordinary exposed concrete. The defects of the original system should be judged in conjunction with its structural repair requirements.
Gaodun recommends making a site trial in a representative area, using the processing, proportioning and coating methods intended for the project, and observing the curing, adhesion and appearance. Transparent solutions in particular need to confirm that gloss, color gain, old stains and repair marks are acceptable.
"Retain the original texture" does not mean "no changes at all after construction." Site trial should be confirmed by the customer rather than just showing a smooth test panel that is different from the actual exterior wall.
4. Why do window frames, cracks and wall moisture need to be designed separately?
These three types of problems, involving structural connections, deformation and moisture migration respectively, cannot be summarized by the same surface treatment.
Window frame joints: connections must accommodate movement and retain drainage
Window frames and walls are made of different materials and may be deformed differently. Details need to confirm the sealing material, bonding interface and compatibility. You cannot just use a thin layer of paint to cover the failed glue joint.
The original drainage holes in the window frame cannot be blocked at will. Building Science Corporation's Info-302 explains that water collected by under-window flashing needs to be able to drain to the outside; blocking the drainage path will destroy its function. [1].
Wall cracks: elongation cannot be directly converted into allowable crack width
Stable shrinkage cracks and repeated opening and closing cracks have different system requirements. It is necessary to determine the nature of the crack before determining a repair, local reinforcement or special joint plan.
The free film elongation of the material does not equal the actual bridging ability after being attached to the wall. Facade substrate, film thickness, low temperature conditions and details all need to match the product evidence. For cracks that continue to expand or are accompanied by obvious deformation, the cause should be identified first.
Wall moisture: To block rainwater, you must also consider how to drain the original moisture
Liquid water barrier and water vapor transmission are different properties. Just because the coating film is "impermeable" does not mean that its moisture permeability is suitable for all walls; nor can it be generally said that all polyaspartic polyurea are impermeable.
The moisture status of the wall is related to factors such as climate, internal and external structure, insulation and air conditioning use. The U.S. Department of Energy Building Science Information also distinguishes between water blocking, air sealing, and moisture vapor control functions. Building Science Education
Based on this, Gaodun believes that the selection of exterior walls should be based on the moisture permeability performance of the specific coating under the designed thickness to evaluate its coordination with the original wall. When there is long-term moisture, alkaline return, or water intrusion from behind, the source should be investigated first before deciding whether to cover the entire film formation.
5. How do consumers purchase and accept inspections to reduce the worry of “washed or leaked”?
Before purchasing, the leakage diagnosis, material scope, and construction responsibilities should be clearly written. Just asking "how much does one square meter of exterior wall cost" makes it difficult to compare the actual work content.
| What should be confirmed | real value to consumers |
|---|---|
| Water seepage sources and treatment scope | Know whether wall, window or upper details are included |
| Product model and film formation mechanism | Avoid confusing different categories of transparent waterproofing |
| substrate and old layer processing | Clarify cleanup, patch, and retention conditions |
| details compatible system | Identify sealing materials, reinforcement and closing practices |
| Coating and film formation requirements | Confirm facade sagging prevention, dosage and thickness control |
| Appearance site trial | Check transparency, gloss and repair marks in advance |
| Inspection and review methods | Agree on controlled water spraying, observation and defect repair |
Facade construction also needs to deal with sags, corners and coverage issues at concave and convex textures. The single-pass coating amount on the roof plane cannot be mechanically moved to the wall, nor can the film thickness be determined to be uniform just by painting it twice.
During the inspection, the applicable water inspection should be carried out after confirming that the curing conditions are met according to the plan, and the scope and observation location should be recorded. The effect of exterior wall maintenance is related to actual wind and rain conditions. A short-term water spray cannot directly prove long-term service life.
The cost should also include necessary substrate, window and crack repairs, as well as actual operating conditions. If high-rise exterior walls are involved, the construction should be organized by personnel with corresponding operating capabilities. Consumers can understand the completion status through process photos and records.
From the perspective of Gaodun's R&D and production, exterior wall products need to pay attention to weather resistance, interface bonding, facade film formation, crack adaptation and matching with wall moisture management. The testing and application records of the corresponding model should support its actual use, and the applicability of all exterior walls cannot be deduced from roof cases alone.
Whether water seepage in exterior walls can be solved with polyaspartic polyurea depends on whether the water inlet path is correct, whether the substrate is reliable, and whether the coating film and details can form a complete protection suitable for the wall.
Note: The specific model, substrate treatment, moisture permeability requirements and details plan are based on on-site investigation, corresponding product documents and engineering design.
References
[1] Building Science Corporation: "Info-302: Pan Flashing for Exterior Wall Openings", 2013-04-15. See instructions for draining flash water under windows. Source (buildingscience.com)