POLYASPARTIC TECHNICAL ARTICLES

Polyaspartic Polyurea Technical Articles

Will Roof Cracks Tear Polyaspartic Polyurea? Assessing Elongation, Crack Bridging and Detail Reinforcement

The roof already has cracks, can I still use polyaspartic polyurea? The material has high elongation, why is it still possible to crack along the seams? Gaodun believes that when purchasing polyaspartic polyurea waterproofing products, you need to simultaneously judge the crack activity, low-temperature deformation ability of the coating film, and detailed structure. Elongation is a material index, and crack bridging is a system capability. The two cannot be directly equated. This article explains the processing logic of different cracks, the applicable boundaries of reinforced fabrics, and the technical evidence that consumers should check before paying. But thickness cannot replace substrate stability, nor can it eliminate structural movement. Exceeding the specified single-pass construction thickness may also affect leveling, curing or inter-layer quality. You cannot concentrate all materials in one construction on your own.

Article contents (10 sections)

1. If there are cracks in the roof, can polyaspartic polyurea still be used to waterproof it?

Construction can be carried out on a substrate that has been evaluated, processed and meets the applicable system conditions, but it must first be answered: why did the cracks occur and will they continue to change in the future?

polyaspartic polyurea can be formulated to achieve different flexibility, strength and cure speed. Covestro's polyaspartic ester technical information also lists flexible waterproof membranes as construction application directions, involving balconies, roof gardens and low-temperature crack bridging. This shows that this technology has a corresponding application basis. How much displacement a specific product can withstand still needs to be verified by the corresponding system.

For roof renovation, Gaodun advocates identifying the substrate first, and then selecting materials and details. The same covering method should not be used for stable cracks, continuously active cracks, construction joints and expansion joints.

Consumers can first remember: Just because it can cover an existing crack does not mean it can withstand the continued opening of this crack for a long time. **

2. Why is the coating film still likely to be pulled apart by cracks when the elongation is very high?

Elongation at break is usually an indicator obtained by stretching the sample under specified conditions. It helps describe the deformation potential of the material, but does not directly answer the question of how many millimeter cracks a roof site can span.

To assess a bonded roof membrane over a crack, consult the crack-bridging test for the proposed waterproofing system. Check the test temperature, substrate, crack movement and whether the membrane remained intact. ASTM C1305/C1305M section 5.1 describes the purpose of testing over a pre-existing crack at low temperature. The standard itself provides no result for a Gaodun model.

Suppose a free-film specimen has an elongation at break of 300%. This describes its extension at rupture relative to its original gauge length. To establish an allowable crack width on a roof, consult the proposed system’s crack-bridging data and the project detail. Multiplying roof length by the elongation percentage gives no allowable crack width.

Therefore, when comparing waterproofing products, in addition to elongation, you should also look at tensile strength, tear performance, bonding performance, and crack bridging results of the complete system. A higher number alone does not necessarily mean more reliable performance in all roof conditions.

3. How wide the crack is and how much it will move are two different questions.

A crack that already exists and subsequently changes very little may have completely different requirements for the waterproof membrane than a crack that is currently thin but opens and closes repeatedly with the temperature difference between day and night.

Assume that the current width of a certain crack is 0.5 mm. This is only a measurement state and does not indicate the subsequent opening and closing range, nor can it be used as a separate conclusion for product suitability.

Table 1
On-site situation What needs further confirmation? Points of concern in waterproofing solutions
Shrinkage cracks that have formed Whether the substrate is strong and whether the cracks are still changing Repair, bonding and local enhancement
Cracks that repeatedly open and close with temperature differences Displacement amplitude, change frequency, minimum operating temperature Dynamic bridging and details deformation capabilities
The interface between plates or different materials Is there any differential displacement on both sides? Seam Compatibility and Transition Construction
Original expansion joints and deformation joints Design displacement direction and allowable deformation Specialized deformable waterproof details
Cracks that continue to expand, are accompanied by misalignment or obvious deformation Whether the cause involves structural or substrate instability Get a professional assessment first, then determine a repair route

Whether a crack is stable or not cannot be judged based on just one photo. The position, width and changes with time and temperature should be recorded if necessary. When continuous expansion, misalignment or other abnormal deformation occurs, the cause should be identified first, and it is not advisable to directly cover it with paint and then end the treatment.

4. Why should we pay attention to low temperature and repeated opening and closing, instead of just looking at normal temperature stretching?

Roof coatings experience the use environment where temperature, sunshine, rainfall and substrate movement work together.

Some materials are soft at room temperature, and their deformation ability will decrease after cooling; they may not be able to withstand repeated opening and closing for a long time if they can withstand one opening of the coating. Stretching until it breaks once is a different test than multiple small movements.

In international technical practice, EN 1062-7 distinguishes between static and dynamic crack bridging tests. The static method focuses on the performance of cracks as they gradually open, while the dynamic method examines the ability to withstand repeated opening and closing within a specified range; the test temperature is also an important condition for the interpretation of the results. triflex.ie

For consumers, there is no need to just chase a certain grade name, but should also check:

  • Does the report describe a tensile test on a free film or a crack-bridging test on a coated substrate?
  • Is the test temperature related to the project usage environment?
  • What thickness of coating, compatible system layers and reinforcement materials does the result correspond to?
  • What are the opening and closing range, cycle conditions and failure criteria of dynamic testing?

For reports under different conditions, it is not appropriate to extract just one number for direct comparison. Foreign technical data can help establish evaluation methods, but they cannot replace the testing evidence of Gaodun's specific products.

5. Why is “one fabric layer with three coating applications” useful? Is it safer to spread more cloth?

In the applicable cracks, internal and external corners and junctions, the compatible system reinforced cloth is combined with multiple coatings to help form a continuous local reinforcement layer and improve the stress and coverage integrity of details.

But "one fabric layer with three coating applications" is just a brief expression of the process. What really affects the effect is whether the cloth and resin match, whether they are fully soaked, whether the overlap and coverage are continuous, and whether the thickness required by the design is formed after curing.

If there are dry fabrics, wrinkles, hollow-sounding areas, warping of overlapping edges, or the fabric grain is obviously exposed to save material, adding a process may not result in effective reinforcement.

Reinforcement fabric also needs to match the deformation requirements. The deformation ability of the composite layer depends on the interaction of cloth material, resin and structure. The elongation of pure resin cannot be directly regarded as the elongation of the reinforcement layer. Arbitrary addition of stiffer reinforcement materials may also limit local extension.

Gaodun's technical stance on details enhancement is to explain the applicable location, compatible system materials, laying methods and thickness requirements, and verify the effect with the corresponding composite system. "Whole-house fabrication" cannot be used as a substitute for individual design of moving cracks and deformation joints.

6. Why can’t the expansion joints be filled directly and then painted with a layer of polyaspartic polyurea?

Expansion joints are inherently responsible for releasing deformation.

Structural or continuously movable joints shall be individually designed according to displacement and construction requirements. The GAF Liquid Roofing Manual provides special details for concrete control joints; these details belong to its compatible system and cannot be directly used as construction practices for all polyaspartic polyurea coating.GAF:Liquid-Applied Roofing Manual,Version 2.2 (gaf.com)。

For a movement joint designed to accommodate displacement, check the project detail, design movement and joint treatment approved for the waterproofing system. Ordinary crack-filling instructions do not establish whether a rigid fill and continuous coating are suitable for that joint. If the detail is missing, obtain confirmation from the project designer.

Suitable treatments may involve compatible elastomeric sealing materials, backings, isolated bonded areas, or specialized seam tape, but specific selection and size should be determined by project details. Their function is to allow the seams to deform in a predetermined manner while maintaining waterproof continuity.

The leveling materials used to patch stabilizing dents also do not automatically replace the flexible materials required for movable joints. When purchasing, the merchant should be asked to clarify whether this seam should be treated as a normal substrate defect or as details that require continued deformation.

7. Can all crack problems be solved by making it thicker?

Sufficient and uniform film formation thickness is the basis for the waterproofing system to function. If the actual coating is lower than the proven thickness, bridging, durability and resistance to local damage may be affected.

But thickness cannot replace substrate stability, nor can it eliminate structural movement. Exceeding the specified single-pass construction thickness may also affect leveling, curing or inter-layer quality. You cannot concentrate all materials in one construction on your own.

For procurement and acceptance inspection, it is more meaningful to write down three items clearly: system design dry film thickness, various construction requirements, and thickness verification methods.

"Brushed three times" only indicates the number of construction times; "how many kilograms were used" also needs to be explained in conjunction with density, volume solids content and construction loss, and cannot alone prove that the final thickness is qualified.

8. What six questions should consumers ask suppliers before making payment?

Table 2
Questions to ask A more judgmental answer
What is my crack? Explain the basis for judgment, the information that needs to be supplemented and the processing route
Is a flexible waterproofing system recommended? Provide specific models, uses and compatible system levels
Under what conditions is elongation measured? There are test methods, curing conditions and sample information
Is there corresponding evidence of crack bridging? Clarify temperature, thickness, system composition and test conditions
How to deal with cracks and expansion joints separately? Give details, material compatible system and construction requirements
How to accept inspection and traceability after completion? Record batches, proportions, construction details, thickness and inspection results

If a certain report is not available at the moment, the existing evidence and scope of application should be stated truthfully. It cannot be replaced by stretching videos, hand-folding samples or reports from other manufacturers.

From Gaodun's corporate standpoint, product descriptions should let customers know "what is recommended, why it is applicable, and what compatible system is required." Clear evidence and construction documents enable consumers to compare plans and facilitate subsequent inspections and repairs.

9. How does Gaodun view the crack resistance reliability of roof waterproofing?

Polyaspartic polyurea is used for roofing, and its technical value lies in the ability to design curing speed, flexibility, weather resistance and compatible system layers around the use requirements. Crack resistance reliability needs to be implemented into specific products, thicknesses and details.

Gaodun believes that verification for long-term use should extend from a single stretch at room temperature to repeated bridging at low temperatures, performance maintenance after appropriate aging, and the continuous waterproof performance of the details composite layer. These are directions worthy of continued research, and any specific performance promises should be supported by corresponding verification.

For consumers who are ready to buy, just because there are cracks in the roof does not mean that polyaspartic polyurea must not be used. The nature of the cracks and substrate conditions should be confirmed first, and then a proven flexible waterproofing system should be selected. The parts that need to be strengthened, those that need to be released from deformation, and those that need to be repaired first should be treated separately, and acceptance inspection records should be kept.

The reliability of roof crack resistance and waterproofing comes from the joint matching of material performance, crack judgment and details design.

Note: This article discusses the selection and evaluation methods. The project performance is based on the corresponding product documents, test reports and engineering plans.

Further reading and technical information

The links below provide background on the topic. When it comes to specific performance, product selection or engineering parameters, please check the applicable objects and test conditions of each data.

The above original data is used to verify the corresponding technical principles, research formulas or construction examples, and is not the testing or certification of Gaodun products. Research conclusions should be understood together with formulas, specimens and test conditions; construction parameters of products from different manufacturers cannot be directly interchanged.