Polyaspartic Polyurea Technical ArticlesCan Polyaspartic Polyurea Be Left Exposed? Choosing Roof and Terrace Systems Based on Material Structure and Protective Layers
After the roof is painted with polyaspartic polyurea, is it still necessary to lay a protective layer of mortar? Can people walk directly onto the terrace? How to choose between transparent, gray and white? Gaodun believes that the polyaspartic polyurea system that has been proven and suitable for exposure can directly face the outdoor environment; whether to add a protective layer, topcoat or decorative layer should be determined according to the use method. This article explains how to choose a complete solution that meets the actual purpose from five aspects: material, protective layer, access, color and cost. Compatible topcoats can be evaluated when increased surface wear resistance, improved cleaning or decorative effects are required. When there are pinholes, insufficient thickness or bonding defects in the bottom layer, they should be repaired first. Topcoat cannot be used as a general remedial layer.
Article contents (6 sections)
1. Why materials can be exposed: The structure provides the basis, and the formula and verification determine the applicability.
The so-called exposed use means that the coating directly withstands sunlight, rain, air and temperature changes, rather than relying on covering layers such as ceramic tiles and mortar above to block the environment.
For polyaspartic polyurea, whether this method can be used depends first on the material structure that forms the coating film.
In Gaodun’s two-component coatings, Part A supplies isocyanate groups and the polyaspartic ester resin in Part B supplies secondary amine groups. When mixed at the mass ratio specified for the model, these groups react to form urea linkages. For flexibility or strength, consult test results for the corresponding cured coating specimen.
For outdoor formulations, choosing an aliphatic or cycloaliphatic isocyanate system will help achieve lightfastness and color retention. Covestro's polyaspartic ester technical information also introduces application directions such as weather resistance, adjustable flexibility and flexible waterproof membranes.
“Aliphatic” describes the chemical structure. For an exposed coating, identify the model, colour and exposure conditions, then request the weathering record for the corresponding specimen. For a project warranty period, check the written warranty terms applicable to that project.
For colour retention on an exposed finish, check the specimen model and colour, test conditions and observations in the weathering record. For strength or flexibility, consult the relevant mechanical test and check its specimen, method and result. A raw material name cannot establish these properties for the complete coating system.
Gaodun believes that exposed applicability should be supported by three levels:
- Structural basis: Describe why the resin and curing agent are suitable for the target environment.
- Finished product verification: Check the corresponding model, color, thickness and test conditions.
- Application Notes: Focus on actual exposure conditions, inspection times, and performance changes.
Among them, color stability, non-powdering of the surface, maintenance of mechanical properties and waterproof continuity should be evaluated separately. A gray sample that has not changed significantly for many years can be used as evidence of appearance observation, but it cannot automatically prove that the overall waterproof performance has not changed.
Accelerated weathering hours also cannot be converted to outdoor years at a fixed ratio. For consumers, the more valuable question is: under what conditions has the model recommended by been verified, and what uses can the results support?
2. Why some waterproof systems need a protective layer: first look at the purpose of protection
Determine whether the roof needs a protective layer from the waterproofing system’s suitability for exposure, expected traffic loads and the project detailing.
| Protective or surface structuring purposes | What problems are mainly solved? | Selection basis |
|---|---|---|
| Reduce environmental exposure | Reduce the direct effects of ultraviolet rays, rain, etc. | Is the waterproof material suitable for exposure? |
| Resistance to mechanical damage | Reduce stepping, impact, drag and concentrated stress | Frequency of use and stress conditions |
| Provide a surface for use | Meet anti-slip, cleaning and decorative needs | Personnel activities and maintenance requirements |
| Cooperate with follow-up projects | Provide conditions for paving, equipment or other structures | Complete roof design and interface compatible system |
For polyaspartic polyurea systems that already have corresponding exposed weather resistance, whether a mortar protective layer is needed should be judged based on the project plan, and it should not be added without purpose just to "look safe".
If furniture, planters or equipment will stand on the terrace, identify the support locations, contact areas and how often the items will move. Check wear or load data for the proposed finish under those conditions before specifying local protection. A weathering record addresses outdoor exposure only.
At the same time, adding a protective layer also requires design. The underlying waterproof layer must not be damaged during construction, and subsequent drainage, joint and maintenance conditions should also be considered. If you plan to lay ceramic tiles, you must also confirm the compatibility of the waterproof layer, interface transition and adhesive material. You cannot assume that the smooth cured surface can be directly pasted.
Gaodun advocates that "why this layer is added" should be explained clearly before deciding on materials and processes. Protective coating, wear-resistant topcoat and decorative paving have different responsibilities and cannot be replaced by each other just by name.
3. What is the difference between occasional maintenance and daily activities: the waterproof layer and the wear-resistant surface layer need to work separately
"You can leave after you are done" is a sentence that is easily misunderstood.
It may simply refer to allowing a short walk-in inspection after curing, or it may refer to long-term use for domestic activities or even frequent public access. These scenes have different material requirements.
Uninhabitable roofs usually have waterproofing and weather resistance as their main tasks, and necessary inspection, cleaning and maintenance conditions must still be maintained. If the equipment maintenance route is fixed, compatible channels or partial protection can be set up according to usage requirements.
Family terrace In addition to being exposed to the sun and rain, it also undergoes drying, leisure, moving items and walking in wet conditions. Wear resistance, anti-slip and cleaning convenience should be considered when selecting.
Yards and high-traffic areas may have more sand brought in, repeatedly stepped on, and items moved, so the floor or traffic surface system needs to be selected based on actual strength.
Tremco's Vulkem 350/351 system consists of a polyurethane substrate and a UV-resistant surface layer. The surface layer with aggregate is used to improve wear resistance and anti-slip. This shows that waterproofing and traffic performance need to be designed according to the system, and the parameters of other brands cannot be directly transferred to Gaodun products.Tremco:Vulkem 350/351 Pedestrian Coating System (tremcosealants.com)。
For primary waterproofing on concrete or tiled roofs and terraces, prefer N300 for prolonged outdoor exposure. Consider N700 for standard weathering requirements. Before retaining old tiles, check for hollow areas, loose tiles and contamination. Prepare a sound, clean, dry surface and verify adhesion of the proposed system on a trial area. In a decorative flake floor, N600 provides the sealing coat and the intermediate coat that receives the flakes. N200 is the clear wear-resistant topcoat. The specific combination should be determined based on the corresponding product documents. An ordinary roof plan cannot be turned into a floor of any strength just by adding a topcoat.
It should also be noted that high surface hardness does not mean that it will not be scratched, wear resistance does not mean that it is resistant to all impacts, and high elongation does not mean that it is suitable for all moving seams.
Consumers should clearly inform the manufacturer: whether people leave every day, whether furniture is placed, and whether there are sand, carts or equipment. In this way, the main waterproof layer and functional surface layer can be selected, instead of continuously adding additional processes after completion.
4. How to choose color and topcoat: decided around appearance, thermal management and usage conditions
Transparent: retain the texture while paying attention to the coating and substrate
The transparent system is suitable for scenes where you want to retain the original appearance of ceramic tiles, stone, etc. But the transparent layer cannot cover all old stains, crack repair marks and substrate color differences.
Transparent also does not automatically mean insulating or completely blocking UV rays. When selecting, you should pay attention to the yellowing resistance, moist and heat appearance and adhesion performance of the transparent coating itself, and evaluate the appearance stability of the substrate after covering.
Grey: unified appearance, still depends on the specific formula
For a grey finish, make a trial patch on the actual substrate using the proposed model and number of coats. Inspect the cured colour, hiding and appearance at application overlaps. For surface temperature or weathering requirements, consult test records for that colour.
Results from gray samples cannot be transferred directly to clear or white models. Performance claims involving color should be supported by evidence of the corresponding color as much as possible.
White: Suitable for solutions focusing on reflected heat, but requires data
White roofs generally reflect sunlight better, and colored roofs using certain pigments may also have higher reflectivity. If cooling is used as a selection condition, the solar reflectance, thermal emissivity and aging data of the corresponding color and structure should be checked. Whether the waterproof layer can be exposed for a long time should also be checked separately for evidence of weather resistance, adhesion and watertightness.U.S. Department of Energy Cool Roofing Guidelines (energy.gov)
Therefore, we cannot rely solely on the white appearance to promise how much lower the indoor temperature will be, nor can we equate thin-layer reflective coating with building insulation. The actual effect needs to be judged based on climate, building structure and measurement conditions.
topcoat with anti-slip: compatible system where required and check final surface
Compatible topcoats can be evaluated when increased surface wear resistance, improved cleaning or decorative effects are required. When there are pinholes, insufficient thickness or bonding defects in the bottom layer, they should be repaired first. Topcoat cannot be used as a general remedial layer.
For wet walking terraces, anti-slip textures should be selected based on shoe soles or bare feet, drainage and cleaning requirements. The coarser and more particles are not better; the degree of coating of the last topcoat will also change the actual surface condition.
Gaodun believes that the complete surface delivered should be evaluated, not just a rough layer during the construction process.
5. How to compare the cost of a complete solution: Calculate the initial construction and subsequent maintenance together.
“Whether one process is saved now will make it easier to rework in the future” depends on whether it is a necessary link or an additional process that does not contribute to the actual use.
For roofs that have exposed conditions and are mainly responsible for waterproofing, it is possible to reduce the number of processes and materials without laying an additional covering layer. For terraces with frequent activities, omitting the necessary wear-resistant, anti-slip or local protection may increase subsequent damage and maintenance burden.
When comparing quotes, the same usage objectives, the same scope and the same evaluation period should be used:
| Expense items | What needs to be compared |
|---|---|
| substrate processing | Old layer removal, surface dusting repair, cleaning and drying |
| details processing | Cracks, internal and external corners, drains, seams and ends |
| Waterproof main layer | Material model, design thickness and actual coating area |
| Surface compatible system | topcoat, non-slip, decorative flakes or other protective decorative construction |
| Construction and acceptance inspection | Process, curing, inspection and defect repair |
| Use and maintenance | Cleaning, spot repairs and resurfacing |
| rework impact | Possible expenses such as demolition, restoration and interruption of use |
You cannot directly compare the quotation for a thin coating with the complete waterproofing and flooring solution; nor can you just look at the price per kilogram and conclude that the total cost is lower. The density, volume solids content, effective thickness and compatible system requirements of different products will affect the actual dosage.
At the same time, it is not appropriate to calculate a seemingly precise “cost per square meter per year” without reliable life and maintenance data. A more practical approach is to clarify what is included in the first construction, what is included in subsequent maintenance, and how to repair local damage.
Gaodun's corporate stance is to let customers know what tasks each material undertakes, and support selection with corresponding testing and usage conditions. For solutions suitable for direct exposure, the basis for exposure should be clearly stated; for solutions that require additional functional surfaces, their purpose and compatible system requirements should also be stated.
The complete value of the consumer purchase is that it will continue to be waterproof, easy to use and maintain under the intended use. By correlating the material structure, exposed evidence, traffic requirements and cost range, we can determine which processes can be reduced and which links must be retained.
Note: The applicable scope, film thickness, topcoat compatible system and usage conditions of the specific model are based on the corresponding product documents, testing evidence and engineering plans.
Further reading and technical information
The links below provide background on the topic. When it comes to specific performance, product selection or engineering parameters, please check the applicable objects and test conditions of each data.
The above original data is used to verify the corresponding technical principles, research formulas or construction examples, and is not the testing or certification of Gaodun products. Research conclusions should be understood together with formulas, specimens and test conditions; construction parameters of products from different manufacturers cannot be directly interchanged.