POLYASPARTIC TECHNICAL ARTICLES
Polyaspartic Polyurea Technical ArticlesMoisture and Ion Transport in Polyaspartic Polyurea: Why Does Surface Water Repellency Not Guarantee Long-Term Waterproofing or Corrosion Protection?
The protective ability of polyaspartic polyurea is related to surface wetting, media absorption, internal diffusion and interface stability. Water contact angle, water absorption and impermeability describe different properties respectively and cannot be replaced by each other. Gaodun combines open experiments and molecular dynamics research to discuss the paths through which moisture and corrosive media enter the coating, as well as verification methods from molecular design to actual protection. When evaluating roofing or industrial protection, contact angle, water absorption, wet adhesion and the protective performance of the actual system can be recorded separately. Each data should indicate the sample, exposure conditions and function corresponding to the test. If long-term protection is the goal, maintenance of performance after exposure also needs to be verified.
Article contents (9 sections)
1. Water beads can roll off, why do we still need to evaluate long-term protection?
No. A hydrophobic surface alone cannot establish long-term resistance to water or ion transport through a coating. Beading and water contact angle describe surface wetting. For the coating system being assessed, measure water uptake over time and test transport of the relevant ion at the specified film thickness, in the intended medium and over a stated exposure period. Check thin spots, pinholes and cracks that could provide a path through the film.
Polyaspartic polyurea performs different tasks on roofs, terraces and industrial metals. Four issues need to be distinguished when evaluating:
- Whether the surface is easily wetted by water.
- How much water a material absorbs under specified conditions.
- How fast does the medium move through the coating?
- After the medium reaches the interface, will it affect adhesion or cause corrosion?
Gaodun believes that the technical judgment of long-term protection requires three levels: surface coverage, coating body and substrate interface.
2. What do hydrophobic, low water absorption and impermeable mean?
| indicator | main description | cannot be proven alone |
|---|---|---|
| Water contact angle | A water contact angle measures surface wetting only. A hydrophobic surface provides no evidence on its own of long-term resistance to water or ion transport through the coating. | Not established by this evidence alone: Water uptake over time, ion transport through the film, or adhesion after wet exposure |
| water absorption | Water absorption performance under specified time and conditions | Not established by this evidence alone: No media transmission or interface damage for a long time |
| water vapor permeability | Water vapor transmission performance under specified conditions | Not established by this evidence alone: Complete waterproofing capability under liquid water pressure |
| Resistance to water penetration under pressure | Records whether water penetrates the specimen at the stated pressure and for the stated duration. | Not established by this evidence alone: Service life under field exposure conditions |
| Wet adhesion | Wet adhesion tests the bond between the coating and the substrate after water exposure. This result alone cannot establish corrosion protection or weather resistance. | Not established by this evidence alone: Overall corrosion protection or weather resistance |
These indicators provide complementary information. They may be related, but there is no fixed conversion relationship that can be used without formula and test conditions.
For example, surface hydrophobic modification can change the contact angle, but whether it improves overall protection requires examining the internal structure, film layer continuity, and adhesion changes.
3. Water entering the complete coating does not necessarily rely on holes visible to the naked eye.
Even if the coating surface is continuous and there are no visible pinholes, it cannot be assumed that moisture transport has ceased completely. For polymers, moisture can first be absorbed in the material and then migrate with chain segment movement and local available space.
Free volume describes the microscopic space associated with molecular packing and is not equivalent to construction bubbles or penetrating pinholes. The free volume distribution, chain segment motion, and water-polymer interaction together influence the transport behavior.
A molecular dynamics study in the "Chinese Journal of Corrosion and Protection" in 2025 compared the structures of different polyaspartic polyurea amine components. The results show that within the scope of its model, ring structure and branching will change the free volume and system density; water molecules can form hydrogen bonds with polyurea and show a tendency to aggregate.
This research suggests that steric hindrance helps to adjust the reactivity of the resin, but it cannot be directly deduced that the final coating must be denser and more water-blocking. **
Gaodun believes that molecular simulation can be used to screen and explain structural differences, but its conclusions still need to be verified with actual coatings under corresponding formula, film thickness and curing conditions.
4. How much water is absorbed and how fast the water passes through need to be studied separately.
Weighing a specimen before and after immersion gives its mass change over that interval. To assess water diffusion, record water uptake over time and measure film thickness. Equation (3) in section 3.1.1 of the DGEBA epoxy coating study (PMCID PMC8009131) uses both quantities to analyse early-stage diffusion. Its diffusion coefficients apply to the epoxy specimens tested.
The lower short-term water absorption rate may come from a lower absorption tendency, or it may be because it is not yet close to equilibrium. Therefore, when comparing data, you need to record both:
- Soaking temperature and time.
- Actual dry film thickness.
- Curing and pretreatment status.
- Surface wiping and weighing methods.
- Composition of the soaking medium.
If there are soluble components extracted from the material during the soaking process, the change in net mass of the sample will also include the effects of water absorption and weight loss. The true degree of water absorption may not be accurately identified based on one weight gain value alone.
Gaodun proposed that research and development should be based on changes in water absorption over time, weight loss on drying after soaking, and wet performance, to avoid comparing only the weight percentage at a certain point in time.
For water immersion after exposure, long-term water accumulation or high humidity environment, it should also be checked whether the original transmission law is still applicable after the material state changes.
5. Why can’t the risk after salt water enters be summarized using pure water tests only?
Pure water immersion helps evaluate water absorption and water resistance, but coastal metal protection also involves salt, interface electrochemical processes and local defects.
To assess long-term resistance to chloride transport, look for a chloride transport test on the specific Gaodun coating at the relevant film thickness, exposure duration and in the relevant medium. Droplet shape describes surface wetting. An uptake test records the specimen’s mass change. Neither measures how much chloride passes through the film.
A public abstract of a 2013 paper in Acta Chemical Engineering shows that researchers used electrochemical impedance spectroscopy to track moist heat tests and used scanning electron microscopy to observe the coating surface. The author divides the failure of the measured system into three stages: electrolyte penetration, substrate corrosion initiation and corrosion expansion based on impedance changes. This test can be used as a reference for tracking the failure process. The failure time of other coatings needs to be verified separately.
The public abstract of a 2025 paper in Materials Letters compares molecular models of dimers, trimers, and silane-modified trimer curing agents. The free volume of the silane-modified trimer model is the lowest, and the corrosion medium diffusion is greatly restricted in the simulation. The comparison of the iron interface effect and friction behavior in this article also comes from simulations. The adhesion, wear and corrosion protection performance of the actual coating film need to be verified by corresponding experiments.
The two types of research jointly support one research and development direction: Part A and Part B should both be included in the design of media transmission and interface protection.
However, experimental studies and molecular models cannot replace the saltwater immersion, corrosion and adhesion verification of actual products.
6. How do thickness and defects change the actual transmission path?
When material properties are similar to other conditions, increasing the complete film thickness can often extend the media transmission path. However, the average thickness cannot represent the protection status of all locations.
Edge films, pinholes, uneven mixing, and localized delamination can all result in a different transfer path than the intact coating. Actual failure may be dominated by thinnest points or defects.
Therefore, Gaodun advocates simultaneous evaluation:
- Actual dry film thickness and its distribution.
- Local minimum thickness and edge coverage.
- Holes, cracks and other defects.
- Curing conditions and interlayer bonding.
- Whether new weak points appear after aging or stress.
"Average thickness increase" cannot be used to directly convert service life, nor can multiple coats of coating be automatically regarded as completely eliminating defects.
7. How to establish a verification combination for waterproof corrosion protection?
Gaodun recommends organizing experiments according to application needs, so that different methods can answer clear questions respectively. The following are R&D evaluation suggestions.
| Evaluation level | Possible methods | main purpose |
|---|---|---|
| surface | Contact angle, surface topography | Identify wetting and surface changes |
| Coating film body | Changes in water absorption over time, weight loss, and swelling | Analyze media entry and material response |
| continuity | Thickness distribution, defect inspection | Identify local weak points |
| interface | Adhesion in dry, wet and re-dried conditions | Compare binding performance in different states |
| metal protection | Electrochemical impedance, scratch corrosion expansion | Tracking Shielding and Interface Corrosion |
| Waterproof system | Impermeability, crack adaptation and retesting after aging | Evaluation of actual waterproof function maintenance |
Electrochemical impedance has time tracking value, but to compare different samples, conditions such as film thickness, area, electrolyte, temperature, and test frequency need to be controlled.
Estimating water absorption from capacitance changes also requires checking the model assumptions and cannot be indiscriminately equated with gravimetric water absorption.
The test sequence should also respond to practical application issues. For example, re-evaluating water resistance after abrasion, or re-testing adhesion after photoaging, can observe whether the previous environmental effects change subsequent protective capabilities.
8. Gaodun’s technical stance: linking surface, transmission and interface design
Shenzhen Gaodun New Materials Co., Ltd. has focused on polyaspartic polyurea systems since 2016, focusing on the research and development, synthesis, formulation and production of Part A and Part B.
Gaodun believes that long-term waterproof corrosion protection research and development should also pay attention to the material's absorption tendency, internal migration, film formation continuity and wet interface stability, and establish evidence through tests of corresponding products.
For roofs and terraces, attention should be paid to whether adhesion, crack adaptation and waterproofing integrity can still be maintained after the action of moisture; for industrial metals, the reaction and damage expansion after the corrosive medium reaches the interface should be further evaluated.
This article is an industry technical analysis and R&D evaluation suggestion. It does not mean that Gaodun has completed all the tests listed. The performance, scope of application and construction requirements of specific models are subject to the corresponding technical instructions and test reports.
Further reading and technical information
The links below provide background on the topic. When it comes to specific performance, product selection or engineering parameters, please check the applicable objects and test conditions of each data.
- Chinese Journal of Corrosion and Protection (2025): Molecular dynamics study of amine structure and corrosion medium diffusion (doi.org)
- Materials Letters (2025): Corrosion and friction simulation of different curing agents polyaspartic polyurea (sciencedirect.com). Check the publisher's public abstract.
- Liu Zhiyuan, Xiong Jinping (2013):Electrochemistry of hygrothermal failure behavior of polyaspartic polyurea coating (hgxb.cip.com.cn), Journal of Chemical Engineering 64(8), 2962–2968. Check journal public abstracts.
The above original data is used to verify the corresponding technical principles, research formulas or construction examples, and is not the testing or certification of Gaodun products. Research conclusions should be understood together with formulas, specimens and test conditions; construction parameters of products from different manufacturers cannot be directly interchanged.