POLYASPARTIC TECHNICAL ARTICLES

Polyaspartic Polyurea Technical Articles

Can Polyaspartic Polyurea Be Applied Directly over Existing Waterproofing? Avoiding Rework over Bitumen, Membranes and Old Coatings

Before deciding whether to overcoat an existing roof, check the existing bond and moisture condition, assess bitumen bleed-through risk where relevant, and verify compatibility and adhesion on a representative site patch.

Article contents (10 sections)

1. If the old waterproofing is not removed, can I apply polyaspartic polyurea directly?

Some old roofs can be renovated with a proven compatible system, but it cannot be determined that they can be directly overcoated just because they have been waterproofed before.

The old waterproofing layer is not a unified substrate. Cement-based coating, polyurethane, acrylic, asphalt coating, modified asphalt membrane and synthetic polymer membrane have different surface properties, aging methods and fixing methods.

Even if they belong to the same kind of material, the state after many years of use may be completely different: some are still firm and continuous, some have been powdered and delaminated, and some have a complete surface but have been dampened internally for a long time.

Gaodun's basic judgment on old roof renovation is: first confirm whether the old system can be retained, and then determine how polyaspartic polyurea is a compatible system. **

For old layers such as rubber asphalt, Gaodun does not recommend direct overcoating without evaluation. If there is no verification of the corresponding model, substrate processing and interface compatible system, the old unsuitable materials should be removed first and restored to a substrate that meets the construction conditions.

2. The new coating is very firmly adhered, why does the whole piece still fall off?

Because "the new coating is firmly stuck to the old coating", only one interface was solved.

Before specifying Gaodun N700 for an existing roof, identify the substrate and any layers to be retained. Page 4 of the Simplified Chinese N700 technical data sheet requires sound, dry, clean concrete or tile. Address hollow or loose areas, contamination and old layers that impair adhesion. For retained tiles, test adhesion on site before deciding whether to coat the full area.

For example, the new polyaspartic polyurea is well bonded to the old coating, but the old coating has detached from the leveling layer and may eventually be lifted off together with the old layer. Adding a new coating thickness will not reconnect the disconnected interface below.

When assessing adhesion, record where the failure occurred: at the interface between the old and new coatings, within the old coating, or in the substrate. A single pull-off adhesion result does not establish whether the entire roof system can be retained long term.

Before overcoating, it is necessary to check the status of the old layer and the moisture content of the substrate, and verify the bonding of the new and old materials. The GAF Liquid Roofing Manual lists substrate treatment, wet area investigation, and on-site adhesion testing as evaluation components for compatible system construction; these principles are not a substitute for model-specific compatibility verification.GAF:Liquid-Applied Roofing Manual,Version 2.2 (gaf.com)。

3. Why do old asphalt and membrane materials need to be judged separately?

Asphalt-based materials vary in their formulations, softening properties, additives and aging levels. Some surfaces may become sticky, migrate, or contaminate subsequent coatings.

The old asphalt substrate needs to be checked for status, water content and compatible system compatibility. GAF's primer coat barrier materials are specifically designed to target color bleeding on existing asphalt roofs, and it cannot be inferred that any primer coat is suitable.GAF: Bleed-Block Asphalt Primer Product Information (gaf.com)。

Consumers are especially likely to be confused about two issues:

First, is the color change the aging of the paint film?

The migration of components in old asphalt may cause contamination and discoloration of the upper light-colored coating. When this kind of phenomenon occurs, the source should be investigated and cannot be directly attributed to the yellowing of polyaspartic polyurea itself.

Second, can primer coat solve all problems?

Internationally, there are specialized renovation systems for specific asphalt roofs. For example, GAF's relevant solutions include moisture inspection, adhesion testing and primer coat to block asphalt bleeding. This shows that overcoating requires a complete design, and it cannot be inferred that any primer coat is suitable for any polyaspartic polyurea product. GAF:Liquid-Applied Roofing Manual,Version 2.2 (gaf.com)。

Primer coat can assume a specific interface or barrier function, but it cannot restore a loose or severely aged membrane to a reliable substrate.

4. What should we look at for different old waterproof layers?

Table 1
Original material or condition Main verification content Selection and processing direction
Cement based old coating Surface dusting, powdering, hollow-sounding areas and bonding status Eliminate weak parts, repair and verify compatible system
Old polyurethane, acrylic coating Aging, Contamination, Interlayer Bonding and Compatibility After treatment, do a trial coating of the corresponding system
Asphalt coating, modified asphalt membrane Stickiness, migration, bulging, overlap and water content It is not suitable to overcoat directly without verification.
PVC, TPO, EPDM and other roll materials Surface properties, aging and fixed system condition Special solutions are needed for this type of membrane
Old silicone coating or sealing residue Material identification, interface bonding and residue range Cannot be treated as ordinary old paint
Roofs that have been repaired many times and whose materials are unknown The position, firmness and internal moisture of each layer Expand the scope of investigation and remove to reliable substrate if necessary

This table is used to illustrate the evaluation direction. It does not mean that all Gaodun models are suitable for all substrates in the table.

Similarly, the construction of ceramic tiles without tile removal and the direct coating of the old waterproof layer belong to different scenarios. Just because the product can be used on solid tiles does not mean it can be used on old waterproofing materials that are soft, migrating or delaminating.

5. If the surface is sun-dried, why do you need to check the internal moisture?

When an old roof leaks, water may get under the membrane, screed or insulation. Just because the surface has dried out in the sun does not mean that the internal moisture has been drained away.

Before overcoating bitumen, a membrane or existing paint, identify the old layer and check its bond and moisture condition. For bitumen, also assess the risk of bleed-through or migration. Prepare a site test patch using the proposed preparation, primer and finish. Verify compatibility and adhesion before deciding whether to retain, repair or remove the existing layer.

GAF's Liquid Roofing Technical Manual lists moisture surveys and adhesion testing as part of the overcoating suitability assessment, requiring identification of damp areas that need to be treated. GAF:Liquid-Applied Roofing Manual,Version 2.2 (gaf.com)。

On-site investigations can be conducted in conjunction with roof construction, leakage recording, testing and local sampling as necessary. Different detection methods have their own applicable scopes, and one surface measurement cannot be regarded as proof that the entire roof interior is dry.

Gaodun believes that renovation plans should identify where the water is coming from, which layers have been affected, and which need to be removed or replaced. Simply extending the surface drying time cannot replace the treatment of internal moisture causes.

6. Do a small site trial first. What should be verified?

Trial coatings are valuable but should be carried out in accordance with the scheme intended for the entire project.

If the site trial area is carefully polished but only cleaned during formal construction, the site trial results cannot represent the actual project. Similarly, the primer coat, ratio, thickness and curing conditions used in the site trial should also correspond to the proposed plan.

Gaodun recommends including the following content into site trial records:

  • The location is representative: Taking into account aging, previous repairs, dampness or other areas with differences.
  • Observe material compatibility: Check for abnormal softening, wrinkling, stickiness, bleeding and curing abnormalities.
  • Check the bond:Evaluate the bond according to applicable methods and record the location of failure.
  • Corresponding conditions of use: Inspection after supplementing appropriate water action or temperature conditions according to project needs.

Picking it with your hands after the surface is dry can only provide very limited information. The site trial inspection time and judgment method should be determined by the corresponding system and cannot be replaced by a unified "if it does not drop the next day, it will pass".

7. What can be kept and what should be cleared?

The processing of old layers can generally be divided into three routes.

Retain and overcoat compatible system: The old system is in good condition, moisture problems have been eliminated or dealt with, the compatibility and bonding ability of new and old materials have been verified, and the details and fixing methods meet the renovation requirements.

Repair after partial removal: The defective area can be reliably identified, the remaining areas are qualified for preservation, and a continuous and compatible connection can be formed between the repair material and the old and new layers.

Entire or large-scale removal: There are problems such as extensive delamination, severe aging, moisture that is difficult to eliminate, or unknown materials. Retaining the old layer cannot establish a sufficiently reliable technical basis.

Judgment cannot be based solely on "the bad area does not look big". Some problems are hidden below the surface, and local repair boundaries need to be confirmed.

Whichever layer is cleared should also be aimed at restoring a reliable substrate. You cannot just shovel off the loose skin and regard the surface dusting and leveling layer below as a qualified substrate.

8. How do consumers compare refurbished prices to avoid later price increases?

For the same quote that says "polyaspartic polyurea roof renovation", the quote may correspond to a completely different scope of work.

Table 2
Quotation items What should be written clearly
Original roof survey Old Material Type, Defects and Moisture Inspection Scope
Old layer processing Basis for retention, partial removal or total removal
substrate repair How to deal with surface dusting, hollow-sounding areas, cracks and drainage defects
compatible system material Models of primer coat, main coating, reinforcement and sealing materials
Overcoat verification Site trial, compatibility and bonding inspection requirements
film formation and acceptance inspection Design thickness, inspection methods, details and records
Scope of responsibility How to define original concealment issues, materials and construction responsibilities

A low quote does not necessarily mean it is cheaper for the same quality if it does not include cleaning, restoration and detail processing.

You can also ask the supplier for clear answers before purchasing: What is the evidence for recommending retaining the old layer? During construction, it is found that the main surface area is affected by moisture or delamination. How to adjust the scope and cost? It is more effective to write these issues into the plan than to argue about it after the project is completed.

9. How does Gaodun understand the technical value of old roof renovation?

For R&D and production companies, the technical capabilities of old roof renovation should be reflected in the ability to identify different substrates, provide a clear compatible system, and verify the durability of the interface.

polyaspartic polyurea has programmable cure, mechanical and weathering properties. Applying these properties to older roofs also requires investigation of bond retention on actual aging surfaces, interlaminar stability after water and temperature effects, and continuity of detail transitions.

Gaodun advocates establishing verification records with specific models, specific old substrates and specific processing techniques, and gradually clarifying the applicable scope. Overcoating cases from other manufacturers can be used as research references and cannot directly replace the applicable evidence of our products.

For consumers, a good renovation plan should explain which old layers are worth keeping, which problems need to be solved first, and what the new waterproofing layer will rely on to work in the long term. Reducing demolition and rework risks requires this basis of judgment.

The reliability of old roof renovation starts with the accurate identification of the original system and is implemented into a proven compatible system between the old and new layers.

Note: This article discusses the evaluation method of old roof overcoating. The specific applicability is based on the corresponding product documents, on-site evaluation and engineering plan.

Further reading and technical information

The links below provide background on the topic. When it comes to specific performance, product selection or engineering parameters, please check the applicable objects and test conditions of each data.

The above original data is used to verify the corresponding technical principles, research formulas or construction examples, and is not the testing or certification of Gaodun products. Research conclusions should be understood together with formulas, specimens and test conditions; construction parameters of products from different manufacturers cannot be directly interchanged.