POLYASPARTIC TECHNICAL ARTICLES
Polyaspartic Polyurea Technical ArticlesDoes Polyaspartic Polyurea Have an Odor? Understanding Low VOC, High Solids and Environmental Test Reports Before Buying
When purchasing polyaspartic polyurea, consumers often ask: Does it have an odor? Is it environmentally friendly? Will terrace construction affect my family? Gaodun believes that these issues need to be judged from product composition, construction status, curing process and usage scenarios. Low odor, low VOC, high solids and low release represent different evaluation contents. This article explains the difference between these concepts and what information consumers should ask manufacturers for. At the durability end, attention should be paid to the materials and maintenance required per unit area to achieve the same protective function and service life. Prolonging reliable use and reducing repeated eradication and rework have the potential to reduce resource consumption; if specific emission reduction claims are to be made, corresponding life cycle data support is still needed.
Article contents (10 sections)
1. Does polyaspartic polyurea have an odor? Can it be directly judged to be environmentally friendly?
When reporting coating odour, identify the finished product model and the state of the sample. Distinguish a component as opened, the mixed coating and the applied film. An odour description in a raw material data sheet applies only to the named raw material.
To verify the VOC content of a two-component coating, check the test report for that model. Identify the components sampled, mix ratio, any added thinner and test method. Odour observations cannot measure VOC content. For example, US EPA Method 24 section 11.2 describes mixing and sampling for multicomponent coatings.
The compatible system of low-viscosity resin and suitable curing agent provides technical space for reducing the consumption of traditional solvents. Covestro's polyaspartic ester data shows that this technology can be used for low-solvent or even near-solvent-free formulation design. This is technical potential, and specific product performance should still be based on testing.
For consumers, "smells little" can describe the feeling, but it does not prove that all relevant substances are not present. Conversely, smelling an odor does not allow you to determine the specific ingredients or level of exposure.
Gaodun advocates explaining the smell experience and verifiable data separately, and avoiding using general promises such as "completely odorless" and "absolutely harmless" to replace product information.
2. Low odor, low VOC, high solids, why are they not the same thing?
| Common saying | What does it mainly explain? | What else needs to be checked? |
|---|---|---|
| low odor | Odour assessment of a specific sample | Identify the model, sample state and assessment conditions. For VOC content, consult the test report for that model. |
| Low VOC | Compare the measured volatile organic compound content with the limit set for that product category by the applicable standard or purchase specification. | Check the product category, limit, units and test method. Follow the specified sample mixing and dilution instructions, including the dilution ratio if required. |
| high solids | The proportion of non-volatile matter under specified test conditions is higher | Whether solids content is reported by mass or by volume, and the test conditions |
| solvent-free | Make a statement regarding the solvent status of the formulation or construction status | Definition, whether to add additional diluent and corresponding information |
| low release | Releases less substances into the air under specified conditions | Release test methods, times and targets |
| Environmental protection test passed | The designated items of the designated sample meet the corresponding requirements | Do the models, items, limits and uses correspond to each other? |
Among them, VOC content and release concentration in the air are particularly easy to be confused.
The former describes the content of the material itself measured according to prescribed methods; the latter is also affected by factors such as construction area, dosage, time, temperature, ventilation and space volume. A content value in a material report cannot be directly used as a measurement result of air quality at a construction site.
3. Why do different reports say "low VOC" but they may not be directly comparable?
Because reports may use different definitions, methods and calculation calibers.
The U.S. EPA pointed out that some VOC definitions used to control outdoor photochemical pollution are not completely consistent with indoor air quality evaluation; some products that are labeled with low VOC according to specific rules cannot judge their indoor air impact solely based on this. U.S. EPA
The practical implications of this for procurement are: when you see "VOC is very low", you should continue to look at what the report measured, how it was measured, and what state it measured.
For two-component products, it should be confirmed whether the test object is Part A, Part B, or the construction materials mixed according to the specified ratio. For processes that allow the addition of diluent, it is also necessary to confirm whether the state after addition is evaluated.
Results expressed in g/L cannot be directly compared with percentages. Without density, calculation basis, and test definition, just comparing numerical sizes may lead to erroneous conclusions.
Gaodun believes that environmental protection promotions should be accompanied by understandable testing standards so that consumers can compare products for the same purpose and under similar conditions.
4. The solids content is close to 100%. Is there no volatilization problem?
High solids generally mean that a larger proportion of the material can be retained as the non-volatile fraction under the corresponding test conditions, helping to reduce reliance on volatile carriers.
However, solids content cannot replace the entire composition analysis, nor can it alone prove that it is odorless, has no specific residues, or is suitable for any space.
Report TL26080331 gives a non-volatile content of 92.6% by mass for the submitted coating sample after Parts A and B were mixed (printed page 5, item 19). Use volume solids to convert between wet and dry film thickness. For VOC content, consult a VOC test report that identifies the method and sample condition. Gaodun test data and scope (gao-dun.com).
Consumers should also look at the entire process: the main coating material has a higher solid content, which does not mean that the primer coat, thinner, and cleaner also have the same characteristics. If solvents from unknown sources are added on site, the promotional data of the original product cannot directly represent the final construction status.
To judge environmental performance, it is necessary to cover the actual combination of materials used, not just a bucket of main paint.
5. Does the two-component reactive film formation mean that no protection is required during construction?
Reactive film formation is conducive to the formation of a cross-linked network, but materials that are not mixed, mixed for construction, and fully cured are in different states.
For two-component systems containing isocyanate components, low VOC or low odor does not mean that contact and inhalation controls can be ignored during construction.
The British HSE's explanation of isocyanate products in the construction field points out that the construction method will affect the exposure. Spraying is usually easier for related substances to enter the air than brushing and rolling. Ventilation and protection should be determined according to the specific product and operation conditions. HSE
For consumers, the most useful thing is to obtain the corresponding safety data sheet (SDS) and construction instructions to confirm the applicable construction methods, ventilation requirements and personnel entry conditions. In the outdoor environment, operations also need to be arranged based on the wind direction and adjacent doors, windows, and air inlets.
Construction protection should be formulated around the actual product. Just because it says "environmentally friendly paint" does not mean that the uncured material and the cured coating film are considered to be in the same contact condition.
6. The surface is dry and the smell is weak. When can it be used normally?
Surface dry, walkable, water-resistant and full performance are often different details.
Polyaspartic polyurea can achieve faster curing through formula, but the specific speed is affected by conditions such as model, ratio, temperature, construction thickness, etc. The return-to-service time of other models or other environments cannot be copied directly.
For rooftops and patios, consumers should specifically ask about:
- When can the next phase of construction begin?
- When can walk-ins be used to inspect or place items?
- When is raining, washing, or required water testing allowed?
- Under what conditions can scheduled use be resumed?
The lighter smell does not prove that all usage requirements have been met; the surface is not sticky, nor can it replace the confirmation of curing status. When abnormal stickiness, softening or persistent abnormal odor occurs, the supplier should be contacted to check the ratio, materials and construction conditions.
Gaodun advocated that these times and applicable conditions should be stated separately in the construction documents to avoid summarizing all opening requirements with one sentence: "Do it quickly".
7. With a RoHS report, does it prove that it is suitable for household and drinking water contact?
Such conclusions cannot be made based on the RoHS report alone.
RoHS-related testing targets restricted substances and corresponding limit values, and is not equivalent to a comprehensive evaluation of construction emissions and indoor air releases, nor is it equivalent to certification of suitability for drinking water or food contact purposes. Whatever was measured in the report, the results should be explained around the corresponding items.
Likewise, experience with a product on a rooftop or decorative outdoor flooring does not automatically extend to drinking fountains, food worktops, or other special contact scenarios.
When consumers check the report, they should confirm the material model, inspection status, project name and scope of application. For special exposure uses, the specific verification required for that use should be requested, rather than accepting one “environmental report” that applies to all scenarios.
8. What types of information are more valuable to obtain from the manufacturer before purchasing?
| information | Main purpose | Verification points |
|---|---|---|
| Technical data sheet TDS | Determine the use, proportion and construction conditions | The model is consistent with the actual purchased product |
| Part A and Part BSDS | Understand the hazard information and protection requirements of each component | File corresponding component and version |
| VOC or related content reporting | Check specific content claims | Method, units and sample status complete |
| Specific substance test report | Determine the results of tested items | Not expanding limited projects to full certification |
| Release test data (if applicable) | Evaluate air release under specified conditions | Related to intended space and purpose |
| Compatible system construction and curing instructions | Clarify construction material combinations and opening conditions | Includes dilution, primer coat and ventilation requirements |
The larger the amount of information, the more sufficient the evidence is. What is more important to consumers is whether the data can correspond to the same product, the same construction status and the same intended use.
In the absence of a particular test, the manufacturer should describe the available evidence and scope of application. Data from other models, other companies, or raw materials suppliers cannot be used to directly prove that our company’s finished products have the same performance.
9. How does Gaodun view the environmentally friendly research and development direction of polyaspartic polyurea?
Gaodun believes that the environmentally friendly research and development of polyaspartic polyurea should also consider the formula composition, construction requirements and long-term use.
On the formulation side, directions worthy of continued research include reducing raw materials residues, reducing unnecessary volatile components, and reducing the need for excessive on-site dilution through viscosity and reaction speed design.
On the product evaluation side, material content testing, actual processes and necessary release evaluation should be gradually linked to make testing closer to customer usage conditions.
At the durability end, attention should be paid to the materials and maintenance required per unit area to achieve the same protective function and service life. Prolonging reliable use and reducing repeated eradication and rework have the potential to reduce resource consumption; if specific emission reduction claims are to be made, corresponding life cycle data support is still needed.
For consumers who are ready to buy, when choosing polyaspartic polyurea, they can ask more specific questions: What is the formula type of the product? What status does the detection correspond to? What kind of protection is needed during construction? What conditions must be met to resume use?
Clear composition instructions, corresponding testing evidence and clear conditions of use can make "environmental protection" product information that can be judged.
Note: Specific VOC, solid content, release and open use conditions are based on the corresponding model documents and test results.
Further reading and technical information
The links below provide background on the topic. When it comes to specific performance, product selection or engineering parameters, please check the applicable objects and test conditions of each data.
The above original data is used to verify the corresponding technical principles, research formulas or construction examples, and is not the testing or certification of Gaodun products. Research conclusions should be understood together with formulas, specimens and test conditions; construction parameters of products from different manufacturers cannot be directly interchanged.