Gaodun GD1520 Polyaspartic Ester Resin in Concrete Protection Research

A 2026 study in Polymers identifies Shenzhen Gaodun New Materials Co., Ltd. as the supplier of N500A and NH1520. Gaodun confirms that the resin it supplied for this study was its GD1520 grade. This article explains how the researchers tested their composite coating and what the results mean for material selection.

Article contents (11 sections)

A 2026 study in Polymers used materials supplied by Shenzhen Gaodun New Materials Co., Ltd. to develop a protective coating for concrete in cold regions. In Section 2.1, the authors identify the isocyanate component as N500A and the resin as NH1520. Gaodun confirms that the resin it supplied for this study corresponds to its GD1520 polyaspartic ester resin. The researchers then formulated, cured and sanded a composite coating. The results below describe that research coating under the stated test conditions. [1]

Which Gaodun materials did the researchers use?

Fengting Li, Pinlu Cao and colleagues investigated whether a coating could repel water, delay droplet freezing and reduce the force needed to remove ice from concrete used in hydraulic structures. They also examined how well the coating retained these properties after abrasion and freeze–thaw cycling. The laboratory substrate was cement mortar. [1]

Table 1
Swipe to see more columns
Material or specimen Identifier in the paper What the identifier refers to Source
Isocyanate component N500A Raw material supplied by Shenzhen Gaodun New Materials Co., Ltd. Paper, Section 2.1
Resin component Bayer polyurea resin NH1520 The paper names Gaodun as the supplier. Gaodun identifies the resin it supplied as GD1520. Paper, Section 2.1, and Gaodun’s product identification
Composite coating Polyurea, silicone and modified silicon carbide Formulated and processed by the research team Paper, Section 2.3
Selected research specimen PURC70–40 The authors’ designation for the formulation evaluated in the tests discussed below Paper, experimental methods and results

To find the resin in the paper, search for NH1520. For a technical enquiry to Gaodun, quote GD1520 and include the paper’s DOI so the supply record can be traced. N500A is the isocyanate component identified in this study. Gaodun’s N500 finished corrosion-protection coating has its own technical data sheet and test records.

What role did the GD1520 resin play?

The resin supplies secondary amine groups that react with isocyanate groups to form urea linkages in the coating matrix. The researchers used infrared spectroscopy to examine the chemical structure of the composite. They also investigated how the silicone component and modified particles influenced the surface of the cured coating. [1]

When adapting this formulation, calculate the isocyanate requirement from the reactive equivalents of the ingredients. Include other active-hydrogen components that can consume isocyanate. After changing a silicone component, filler or additive, check the mix ratio, working time, cure, surface condition and mechanical properties. The resin grade alone cannot predict the surface produced by a particular formulation and sanding procedure.

How did the researchers measure water repellency?

A water contact angle describes the shape of a droplet resting on the surface. A roll-off angle gives the tilt at which the droplet starts to move. A photograph can show beading, but measuring both angles reveals whether a beaded droplet also rolls off readily.

The researchers dispersed silicon carbide particles treated with dodecyltriethoxysilane in a polyurea–silicone matrix. After curing, they sanded the coating to expose particles and create a rough surface. Using 5 μL droplets of deionized water, they measured a water contact angle of approximately 151° and a roll-off angle of approximately 9° on PURC70–40. They attributed the result to the combination of surface roughness and low surface energy. [1]

For a roof or concrete protection project, assess film continuity, adhesion and detailing separately. A field sample can show water beading in the middle while a gap at an edge still leaves the substrate exposed.

What did the abrasion test establish?

The researchers placed PURC70–40 against 800-grit sandpaper under a 500 g load. The stroke length was 20 cm. One complete forward-and-back motion counted as one cycle. The coating maintained a high water contact angle throughout 500 cycles. The authors proposed that abrasion exposed additional hydrophobic particles within the coating, helping the worn surface retain its water repellency. [1]

For a project-specific trial, record remaining film thickness, visible defects and any particle loss alongside the water contact angle. Choose an abrasion method that reflects the intended exposure, such as grit under footwear, cleaning equipment or sediment carried by water. A laboratory cycle count can support comparisons between specimens tested by the same method. Estimating service life also requires field exposure data.

How did the coating affect freezing and ice removal?

For the droplet-freezing test, the researchers pre-cooled the specimens at −18 °C for 3 hours. They then placed a 20 μL water droplet on each surface. The water was at −2 °C immediately before deposition. Complete freezing took an average of 24 seconds on bare mortar and 266 seconds on sanded PURC70–40. In a separate shear test, ice adhesion strength was approximately 1,240 kPa on bare mortar and 37 kPa on the coated surface. The first test measured time to freeze. The second measured resistance to ice removal. [1]

For a cold-region trial, identify how water reaches the surface, the surface temperature and the type of ice expected. Frost, freezing rain and pooled water present different conditions from an isolated laboratory droplet. Where repeated de-icing is expected, inspect the coating for damage and exposed substrate, then retest adhesion. For pedestrian or vehicle traffic, evaluate slip resistance separately under the relevant wet or icy conditions.

What did 100 freeze–thaw cycles show?

The researchers dried the coated mortar specimens and sealed the uncoated faces with epoxy resin. Each cycle consisted of 6 hours of freezing at −18 °C followed by 6 hours of thawing at 60 °C. After 100 cycles, they observed no visible cracking or delamination of the PURC70–40 coating. They also evaluated the surface properties of the coating and the mechanical properties of separately prepared free films. [1]

The sealing procedure matters when interpreting this result. On site, concrete may absorb water through its back face, joints or cracks. A representative field trial should account for those moisture pathways and assess adhesion, surface condition and deformation at low temperature. If the installation will also face sunlight, salt or standing water, obtain evidence for those exposures before estimating service life.

Why report where a pull-off specimen failed?

The researchers formed circular PURC70–40 specimens 20 mm in diameter and 2 mm thick on mortar. They applied tensile load perpendicular to the surface at a crosshead speed of 50 mm/min. Across three specimens, the mean apparent pull-off strength was approximately 2.39 MPa. Failure occurred mainly within the mortar, which limited the measured strength. The test therefore does not give the intrinsic strength of the coating–mortar interface. [1]

A useful pull-off report identifies the substrate, its age and preparation, the primer, film thickness, curing conditions and failure location. On an existing tiled terrace, for example, a coating may adhere well to a tile while the bedding beneath the tile comes loose. Check for hollow or loose tiles, weak or dusty concrete, residual coatings and persistent dampness before applying the system over the full area.

For site verification, prepare a test area on the actual substrate using the proposed cleaning method, primer and coating. Inspect it after the agreed curing period. Set acceptance criteria for the specified product, substrate and project conditions.

What should formulators and project buyers request?

A formulator evaluating GD1520 needs the data required to select a compatible isocyanate and establish a mix ratio. A buyer specifying a finished coating also needs evidence for the complete system on the intended substrate.

Table 2
Intended use Documents or observations to request Question to resolve
Raw material formulation Resin and hardener technical data sheets, batch records and reactive equivalent weights Does the proposed mix ratio give the required working time and cure?
Functional surface development Particle treatment and dispersion records, finishing procedure and test methods How is the surface produced, and how well does it retain its function after wear?
Concrete protection Substrate condition, primer specification, film thickness, adhesion results and defect inspection Will the complete system bond reliably to the prepared substrate?
Cold-region trial Target temperatures, icing conditions, freeze–thaw protocol and results after de-icing Does the coating retain its function and integrity under the intended conditions?
Long-term outdoor exposure Weathering data for the specified finished product, field records and maintenance plan How closely does the evidence match the installation environment?

When contacting Gaodun, include the application location, substrate type, photographs, expected temperatures, exposure to water or chemicals, proposed application method and acceptance criteria. These details help define a suitable trial formulation or field test.

Frequently asked questions

How does Gaodun GD1520 relate to NH1520 in the paper?

NH1520 is the designation used in the paper. Shenzhen Gaodun New Materials Co., Ltd. confirms that the resin it supplied for this particular study corresponds to its GD1520 grade.

Does the paper identify Gaodun as a supplier?

Yes. Section 2.1 identifies Shenzhen Gaodun New Materials Co., Ltd. as the supplier of both N500A and NH1520. The authors describe their formulation, surface treatment and testing in the experimental sections. [1]

Will mixing GD1520 with a hardener reproduce the superhydrophobic surface?

Reproducing the reported surface also requires control of the silicone component, modified particles, dispersion, curing and sanding. Verify the mix ratio against current material specifications and test the resulting surface under defined conditions. [1]

Can the study serve as a performance report for Gaodun N300, N700 or N500?

The paper tested the researchers’ composite formulation. For any of these finished products, request the model-specific technical data sheet and test records covering the proposed system, substrate and film thickness.

Can the contact angle or freeze–thaw result establish a roof’s waterproofing service life?

Neither measurement establishes a service life in years. A roof assessment also needs evidence on substrate adhesion, crack and joint detailing, weather exposure, installed film thickness, workmanship and maintenance.

How can a buyer use this study when evaluating Gaodun raw materials?

Use the paper to trace the material source and identify test methods relevant to your application. Combine that information with current product data, batch records and trials on representative substrates.

Gaodun’s technical assessment

The paper documents a research application for resin supplied by Gaodun and identified by the company as GD1520. For formulators, it shows why the reactive matrix, particle dispersion and surface finish need to be evaluated together. For project buyers, the most informative test is one that uses the proposed coating system on a representative substrate and records both the measured result and the way the specimen failed or changed.

References

[1] Li, F., Cao, P., Bo, K., Ge, Z., Wang, M., and Guo, M. (2026). Durable Superhydrophobic Polyurea Coating with Anti-Icing Properties for Hydraulic Concrete Protection. Polymers, 18(22), 2922. Published 20 November 2026. See Section 2.1 for the materials, Sections 2.2–2.8 for preparation and testing, and Section 3 for results. Publisher’s full text (mdpi.com) · DOI (doi.org). Accessed 27 November 2026.

Material identification. The paper identifies the resin as NH1520. Shenzhen Gaodun New Materials Co., Ltd. confirms that the resin it supplied for this study corresponds to its GD1520 grade.