How do I choose a grade for concrete roofs, tiled roofs and terraces?
For waterproofing concrete roofs, tiled roofs and terraces, choose N300 for long-term weather resistance and N700 for standard weather resistance. Check substrate soundness, drainage, cracks and any existing waterproofing layers. The typical total application rate for the N300 or N700 main roof waterproofing layer is 1.3 kg/m², yielding approximately 1.2 mm of film. Before retaining existing tiles, repair hollow or loose areas. Clean, dry and abrade the tiles, then test adhesion on a small area of the actual tiles. The rate and thickness are reference values for the main coating. Allow separately for detailing, substrate absorption and application losses.
My tiled terrace leaks and I want to keep the original tile pattern. Should I use N700 or just apply clear N200?
Neither option on its own meets both requirements. Light grey N700 covers the tile pattern. Adding clear N200 over N700 cannot reveal the pattern underneath. N200 is a clear topcoat and cannot repair an existing leak on its own. Locate the water entry point and inspect joints, drains and the existing waterproofing before choosing a waterproofing system and detailing repairs. To retain the pattern, test the proposed system on the actual tiles for appearance, adhesion and compatibility between coats.
Can I use quartz sand to fill a concrete crack if white fused alumina is unavailable?
Yes, for a stable, nonstructural concrete crack. If white fused alumina is unavailable locally, use dry quartz sand in the same filling procedure. Confirm the particle size and amount for the coating grade and repair design. Moving cracks, structural cracks and movement joints require a separate treatment design.
Can I use the 1:1 ratio in the slip-resistant tile finish video to fill cracks or mix Parts A and B?
No. In this finish, 1:1 is the mass ratio of aggregate to mixed coating. First mix Parts A and B as specified in the grade-specific TDS. Then add 1 kg of the selected aggregate per 1 kg of mixed coating. This finish uses 80–100 mesh white fused alumina or quartz sand and requires a wet slip-resistance trial. Confirm the filler amount for crack repairs separately.